Skip Navigation
Skip to contents

Diabetes Metab J : Diabetes & Metabolism Journal

Search
OPEN ACCESS

Articles

Page Path
HOME > Diabetes Metab J > Volume 47(1); 2023 > Article
Original Article
Type 1 Diabetes Performance of Fast-Acting Aspart Insulin as Compared to Aspart Insulin in Insulin Pump for Managing Type 1 Diabetes Mellitus: A Meta-Analysis
Deep Dutta1orcidcorresp_icon, Ritin Mohindra2, Kunal Mahajan3, Meha Sharma4
Diabetes & Metabolism Journal 2023;47(1):72-81.
DOI: https://doi.org/10.4093/dmj.2022.0035
Published online: June 24, 2022
  • 6,033 Views
  • 268 Download
  • 1 Web of Science
  • 3 Crossref
  • 4 Scopus

1Department of Endocrinology, Center For Endocrinology Diabetes Arthritis & Rheumatism (CEDAR) Superspeciality Healthcare, New Delhi, India

2Department of Medicine, Postgraduate Institute of Medical Education and Research, Chandigarh, India

3Department of Cardiology, Holy Heart Advanced Cardiac Care Center, Rohtak, India

4Department of Rheumatology, CEDAR Superspeciality Healthcare, New Delhi, India

corresp_icon Corresponding author: Deep Dutta orcid Department of Endocrinology, Center For Endocrinology Diabetes Arthritis & Rheumatism (CEDAR) Superspeciality Healthcare, Dwarka Sector 13, New Delhi 110075, India E-mail: deepdutta2000@yahoo.com
• Received: February 1, 2022   • Accepted: March 15, 2022

Copyright © 2023 Korean Diabetes Association

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

prev next
  • Background
    No meta-analysis has analysed efficacy and safety of fast-acting aspart insulin (FIAsp) with insulin pump in type 1 diabetes mellitus (T1DM).
  • Methods
    Electronic databases were searched for randomised controlled trials (RCTs) involving T1DM patients on insulin pump receiving FIAsp in intervention arm, and placebo/active comparator insulin in control arm. Primary outcome was to evaluate changes in 1- and 2-hour post-prandial glucose (1hPPG and 2hPPG). Secondary outcomes were to evaluate alterations in percentage time with blood glucose <3.9 mmol/L (hypoglycaemia), time in range (TIR) blood glucose 3.9 to 10 mmol/L, insulin requirements and adverse events.
  • Results
    Data from four RCTs involving 640 patients was analysed. FIAsp use in insulin pump was associated with significantly greater lowering of 1hPPG (mean difference [MD], –1.35 mmol/L; 95% confidence interval [CI], –1.72 to –0.98; P<0.01; I2=63%) and 2hPPG (MD, –1.19 mmol/L; 95% CI, –1.38 to –1.00; P<0.01; I2=0%) as compared to controls. TIR was comparable among groups (MD, 1.06%; 95% CI, –3.84 to 5.96; P=0.67; I2=70%). Duration of blood glucose <3.9 mmol/L was lower in FIAsp group, approaching significance (MD, –0.91%; 95% CI, –1.84 to 0.03; P=0.06; I2=0%). Total hypoglycaemic episodes (risk ratio [RR], 1.35; 95% CI, 0.55 to 3.31; P=0.51; I2=0%), severe hypoglycaemia (RR, 2.26; 95% CI, 0.77 to 6.66; P=0.14), infusion site reactions (RR, 1.35; 95% CI, 0.63 to 2.93; P=0.77; I2=0%), and treatment-emergent adverse events (RR, 1.13; 95% CI, 0.80 to 1.60; P=0.50; I2=0%) were comparable.
  • Conclusion
    FIAsp use in insulin pump is associated with better post-prandial glycaemic control with no increased hypoglycaemia or glycaemic variability.
Insulin pumps, based on closed loop systems are recommended for managing type 1 diabetes mellitus (T1DM). Hybrid close loop systems typically have associated continuous glucose monitoring (CGM) using proprietary algorithms which help in adjusting insulin infusion rates with the aim of proving better glycaemic control with lower risks of hypoglycaemia [1]. However one issue which remains a challenge even with the best of close loop system insulin pumps is the slower than physiologic absorption of analogue mealtime insulin like insulin glulisine, insulin lispro or insulin aspart, making postprandial blood glucose control difficult [2]. Fast-acting aspart insulin (FIAsp) is a novel insulin that contains niacinamide and l-arginine resulting in faster initial absorption of insulin aspart (IAsp). FIAsp subcutaneously has been shown to have greater early glucose lowering effect than aspart insulin [3]. Clamp studies have confirmed 57% earlier onset of appearance and a 35% earlier time to reach 50% maximum concentration for FIAsp as compared to aspart insulin [4]. In a pooled analysis of data from 218 adult people with T1DM from six randomised controlled trials (RCTs), comparing subcutaneous FIAsp injections with subcutaneous aspart injections revealed FIAsp potential to better mimic the physiologic prandial insulin secretion and thereby to improve post-prandial glucose control compared to aspart insulin [2].
Hence mechanistically FIAsp insulin should be better for using in insulin pumps as compared to aspart and other analogue short acting insulins. There have been several RCTs published evaluating the role of FIAsp with different insulin pumps [5]. However till date, no meta-analysis have been published evaluating the performance of FIAsp insulin in insulin pump devices. This meta-analysis was undertaken to address this knowledge-gap.
Methodology
The meta-analysis was carried out according to the recommendations of the Cochrane Handbook for Systematic Reviews of Interventions [6]. The predefined protocol has been registered in the International Prospective Register of Systematic Reviews (PROSPERO) having Registration number of CRD42021291584. All RCTs published till October 2021 were considered for this meta-analysis. This meta-analysis has been reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) [6]. Since ethical approval already exists for the individual studies included in the meta-analysis, our review was exempt from ethics approval.
The PICOS (patient, intervention, control, outcome and study type) criteria was used to screen and select the studies for this meta-analysis, with patients (P) being people living with T1DM; intervention (I) being use of FIAsp insulin in insulin pump device for managing T1DM; control (C) being patients either on any other approved insulin in insulin pump for managing T1DM; outcomes (O) being evaluated were impact on blood glucose parameters, time in range (TIR), hypoglycaemia and any adverse effects noted. Only patients with T1DM were considered for this meta-analysis. Only those studies were included in this meta-analysis which had at least two treatment arms/groups, with one of the groups having patients with T1DM on FIAsp in insulin pump and the other arm/group receiving any other insulin in place of FIAsp in insulin pump.
The primary outcomes were to evaluate the changes in 1- and 2-hour post-prandial glucose (1hPPG and 2hPPG). The secondary outcomes of this study was to evaluate alterations in different parameters of CGM like percentage of time in blood glucose <3.9 mmol/L, TIR blood glucose 3.9 to 10 mmol/L, daily insulin requirements, hypoglycaemia, and adverse events.
Search method for identification of studies
A detailed electronic databases of Medline (Via PubMed), Embase (via Ovid SP), Cochrane central register of controlled trials (CENTRAL) (for trials only), ctri.nic.in, clinicaltrials.gov, global health, and Google scholar were searched using a Boolean search strategy: (fast acting aspart) OR (aspart insulin) AND (diabetes).
Data extraction and study selection
Data extraction was carried out independently by two authors using standard data extraction forms. In cases where more than one publication of a single study group were found, results were grouped and relevant data from each report were used in the analyses. Data on the primary and secondary outcomes as stated above was extracted. Patient characteristics (including demographic information and comorbidities) from the different studies included in the analysis were noted in a tabular form (Table 1). All disagreements were resolved by the third and fourth authors. The flow of data extraction and study selection has been elaborated in Supplementary Fig. 1.
Assessment of risk of bias in included studies
Three authors independently assessed the risk of bias using the risk of bias assessment tool in Review Manager (Revman) version 5.3 (The Cochrane Collaboration, Oxford, UK, 2014) software. The different types of bias looked for have been elaborated in a previous metanalysis by our group [7].
Measures of treatment effect
For continuous variables, the outcomes were expressed as mean difference (MD). International System (SI) units were used for analysis, and all studies reporting results in conventional units were converted to SI units for analysis. RevMan version 5.3 was used for comparing different primary and secondary outcomes between FIAsp insulin and control group.
Assessment of heterogeneity
Heterogeneity was initially assessed by studying the forest plot generated for the primary and secondary outcomes. Subsequently heterogeneity was analysed using a chi2 test on N-1 degrees of freedom, with an alpha of 0.05 used for statistical significance and with the I2 test [8]. The detail of assessment and interpretation of heterogeneity has already been elaborated elsewhere [7].
Grading of the results
An overall grading of the evidence (certainty of the evidence) related to each of the primary and secondary outcomes of the meta-analysis was done using the Grades of Recommendation, Assessment, Development and Evaluation (GRADE) approach [9]. The details of how grading of the study results was done and how the summary of findings table was developed (Table 1) has been elaborated elsewhere [7]. Publication bias was assessed by plotting the funnel plot, which specifically targets small study bias, in which small studies tend to show larger estimates of effects and greater variability than larger studies [9]. Presence of one or more of the smaller studies outside the inverted funnel plot was taken as evidence of presence of significant publication bias [10]. The funnel plots of the key outcomes of this study have been elaborated in Supplementary Fig. 2.
Data synthesis
Data was pooled as random effect model for the analysis of primary and secondary outcomes. The outcomes were expressed as 95% confidence intervals (CIs). Forrest plots were plotted with the left side of the graph favouring FIAsp insulin and the right side of the graph favouring control using RevMan 5.3 software. P<0.05 was considered statistically significant.
A total of 257 articles were found after the initial search (Supplementary Fig. 1). Following the screening of the titles, abstracts, followed by full-texts, the search was reduced down to 105 studies which were evaluated in detail for inclusion in this meta-analysis (Supplementary Fig. 1). Four RCTs which fulfilled all criteria were analysed in this meta-analysis [5,11-13].
In the study by Ozer et al. [5], 40 people with T1DM were randomized to receive FIAsp or aspart insulin through Med-tronic 670G system in a cross-over fashion. In the study by Boughton et al. [11], 25 people with T1DM were randomized to receive FIAsp or aspart insulin through the Dana Diabecare RS insulin pump, where the insulin delivery is directed through the CamAPS FX app (CamDiab, Cambridge, UK) which resides on an any Android phone, that receives sensor glucose data from the Dexcom G6 transmitter creating a closed loop system. In the study by Klonoff et al. [12], 472 people with T1DM were randomized to receive either FIAsp or aspart insulin through MiniMed530G insulin pump (Paradigm Veo, Paradigm Revel or Paradigm, Medtronic Inc., Minneapolis, MN, USA) for continuous subcutaneous insulin infusion therapy. In the study by Hsu et al. [13], 19 people with T1DM were randomized to receive either FIAsp or aspart insulin through MiniMed670G insulin pump (Medtronic, Northridge, CA, USA). The duration of study was 6, 8, 16, and 2 weeks respectively in the RCTs by Ozer et al. [5], Boughton et al. [11], Klonoff et al. [12], and Hsu et al. [13] respectively, after which cross-over switch was done for the study participants for same time period.
The RCT by Russel et al. [14] was excluded as it used only FIAsp insulin with different settings of the insulin pump in the three different arms of the RCT. The study by Grosman et al. [15] was excluded as it was done using a virtual patient simulation and not in real patients. The study by Tsoukas et al. [16] was excluded as it used pramlintide along with FIAsp insulin in the insulin pump closed loop system. The details of the studies included in this meta-analysis have been elaborated in Table 1.
Risk of bias in the included studies
The summaries of risk of bias of the four studies included in the meta-analysis have been elaborated in Fig. 1. Random sequence generation, allocation concealment, attrition bias and, reporting bias were judged to be at low risk of bias in all the four studies (100%). Performance and detection bias were low risk in three out of four studies (75%). Source of funding, especially pharmaceutical, authors from the pharmaceutical organizations and conflict of interests were looked into the “other bias” section. Other bias were judged to be at low risk in two out of four studies (50%) (Fig. 1). Further details have been elaborated in Supplementary Table 1.
Effect of FIAsp on primary outcomes

One-hour and 2-hour post-prandial glucose

Data from two studies involving 535 people with T1DM was analysed to find out the impact of FIAsp on 1hPPG. Individuals receiving FIAsp had significantly greater lowering of 1hPPG as compared to those receiving conventional aspart insulin (MD, –1.35 mmol/L; 95% CI, –1.72 to –0.98); P<0.01; I2=63% for moderate heterogeneity) (Fig. 2A). Data from two studies involving 552 people with T1DM was analysed to find out the impact of FIAsp on 2hPPG. Individuals receiving FIAsp had significantly greater lowering of 2hPPG as compared to those receiving conventional aspart insulin (MD, –1.19 mmol/L; 95% CI, –1.38 to –1.00; P<0.01; I2=0% for low heterogeneity) (Fig. 2B).
Effect of FIAsp on secondary outcomes

Insulin requirements

Data from four studies involving 640 people with T1DM was analysed to find out the impact of FIAsp on daily bolus insulin requirement and well as total daily insulin requirement via the insulin pump as compared to those receiving aspart insulin. Daily bolus insulin requirement (MD, –0.03 U; 95% CI, –1.60 to 1.54; P=0.97; I2=0% for low heterogeneity) (Fig. 2C) as well as total daily insulin requirement (MD, 1.09 U; 95% CI, –1.62 to 3.81; P=0.43; I2=0% for low heterogeneity) (Fig. 2D) were similar among the two study groups.
CGM glycaemic parameters
Data from two studies (88 patients) were analysed to evaluate the impact of using FIAsp insulin in place of conventional aspart insulin in insulin pump on the TIR, defined as percentage time having blood glucose in the range of 3.9 to 10.0 mmol/L, and on time in hypoglycaemia on CGM, defined as percentage time having blood glucose <3.9 mmol/L. TIR was comparable among the two study groups (MD, 1.06%; 95% CI, –3.84 to 5.96; P=0.67; I2=70% for moderate heterogeneity) (Fig. 3A). Time in hypoglycaemia was lower among patients receiving FIAsp as compared to conventional aspart insulin, which approached statistical significance (MD, –0.91%; 95% CI, –1.84 to 0.03; P=0.06; I2=0% for low heterogeneity) (Fig. 3B).
Glycosylated hemoglobin reduction
Data from one study involving 472 patients [12] was available analysing percentage of people achieving glycosylated hemoglobin (HbA1c) <7% (53 mmol/mol). The percentage of people achieving glycaemic targets was comparable among the two study groups (MD, 0.84; 95% CI, 0.54 to 1.3; P=0.44). In the study by Ozer et al. [5], HbA1c reduction was marginally better in the FIAsp group (–0.06%) as compared to the aspart group, but statistically not significant.
Safety
Data from three studies (590 patients) was analysed to evaluate the impact of FIAsp as compared to aspart insulin on the occurrence of total hypoglycaemic episodes and severe hypoglycaemia episodes. The occurrence of total hypoglycaemic episodes (risk ratio [RR], 1.35; 95% CI, 0.55 to 3.31; P=0.51; I2=0% for low heterogeneity) high certainty of evidence (Fig. 3C) and severe hypoglycaemia episodes (RR, 2.26; 95% CI, 0.77 to 6.66; P=0.14) (Fig. 3D) was comparable among two study groups. Data from four studies (640 patients) was analysed to evaluate impact of FIAsp insulin as compared to aspart insulin on occurrence of adverse events (treatment-emergent adverse events [TAEs] and severe adverse events [SAEs]). The occurrence of TAEs (RR, 1.13; 95% CI, 0.80 to 1.60; P=0.50; I2=0% for low heterogeneity) (Fig. 4A) and SAEs (RR, 1.00; 95% CI, 0.25 to 4.05; P=1.00) (Fig. 4B) were not significantly different among the two study groups.
Data from two studies (552 patients) was analysed to evaluate the occurrence of insulin infusion site reactions in patients receiving FIAsp as compared to aspart insulin. The occurrence of infusion site reactions was comparable across the study groups (RR, 1.35; 95% CI, 0.63 to 2.93; P=0.77; I2=0% for low heterogeneity) (Fig. 4C). Data from four studies (640 patients) was analysed to evaluate the occurrence of occlusion episodes in patients receiving FIAsp as compared to aspart insulin. The occurrence of infusion site reactions was comparable across study groups (RR, 0.95; 95% CI, 0.65 to 1.41; P=0.81; I2=0% for low heterogeneity) (Fig. 4D). The summary of findings of the key outcomes of this study has been elaborated in Table 2.
The story of development of prandial insulins have always been about faster onset of action to mimic as close as possible to endogenous prandial insulin secretion. Monomeric insulins like conventional aspart insulin, lispro insulin, and apidra insulin were found to be better than regular human insulin with regards to control of post-prandial glycaemic excursions both in T1DM and type 2 diabetes mellitus, with increased treatment satisfaction especially in people living with T1DM [17,18]. A recent meta-analysis documented subcutaneous aspart and lispro insulin injections to be more effective in controlling 1-hour and 2-hour post meal hyperglycaemia without any increase in hypoglycaemia or glycaemic variability [17]. FIAsp insulin is a further advancement in the field of monomeric insulins towards faster onset of insulin action. Heise et al. [2] in a pooled analysis of pharmacology trials data showed that subcutaneous FIAsp insulin injection use was associated with 4.9 minutes (95% CI, –5.3 to –4.4) earlier onset of action, two times greater exposure to insulin in the first 30 minutes post-injection, 74% greater (odds ratio, 1.74; 95% CI, 1.47to 2.10) early glucose lowering effect in the first 30 minutes postinjection and 12.2 minutes (95% CI, –17.9 to –6.5) earlier offset of exposure, as compared to monomeric aspart insulin. FIAsp insulin when administered subcutaneously up to 20 minutes after the start of meals continued to provide similar glycaemic control as compared to pre-prandial aspart insulin administration [19]. Our meta-analysis showed that these pharmacokinetic and pharmacodynamic benefits actually translates into meaningful clinical benefits when FIAsp insulin is used in insulin pump.
This is the first meta-analysis to highlight the glycaemic efficacy and side effect profile of FIAsp insulin as compared to aspart insulin in insulin pumps for managing T1DM. Over 2 to 12 weeks of clinical use, FIAsp had similar glycaemic efficacy as compared to aspart in insulin. FIAsp performed significantly better than aspart insulin with regards to control of 1hPPG and 2hPPG. Percentage of time spent in TIR on CGM was comparable for both the insulins. FIAsp use was associated with lower time spent in hypoglycamia range (<3.9 mmol/L) which approached statistical significance. Total daily insulin dose requirement was marginally higher with FIAsp but not statistically significant. Totally hypoglycaemia and severe hypoglycaemic episodes were comparable across both the insulin groups. Also TAEs, SAEs, infusion site reaction, and occlusions were not different with regards to FIAsp or aspart insulin use. The accelerated absorption kinetics of FIAsp insulin suggested that when switching to FIAsp in insulin pump, the bolus dosing will need to be adjusted to reduce the potential risk of early post‐prandial hypoglycaemia or late post‐prandial hyperglycaemia [20]. A good understanding of glycaemic index and the meal composition would further help in improving the glycaemic outcomes.
Limitations of this meta-analysis include the relative small number of patients in few studies. Three of the four studies used hybrid closed loop insulin pump system, and one study used conventional insulin pump with CGM. Hence analysing them together is also a limitation of this study. However sub-group analysis could not be done as there was only one study in the conventional insulin pump with CGM sub-group. The duration of study was short in most of the studies. Hence long term impact on HbA1c is not available from this meta-analysis. This meta-analysis highlights the need for larger RCTs with longer follow-up of at least 1 year to evaluate the efficacy, safety and glycaemic durability of FIAsp insulin in insulin pump as compared to other short acting insulin. The cost of one 3 mL cartridge of 100 IU/mL of FIAsp insulin is similar to marginally lower than conventional aspart insulin (Novorapid, Novo Nordisk, Bagsværd, Denmark) and lispro insulin (Humalog, Eli Lilly, Indianapolis, IN, USA) is different countries across the globe [21-24].
To conclude it may be said that FIAsp insulin may be considered as the best available mimic of the physiologic prandial insulin secretion. This meta-analysis provides us with reassuring data that use of FIAsp insulin in insulin pump is advantageous cause of better post-prandial glycaemic control with no increased risk of hypoglycaemia or glycaemic variability. Fiasp is a useful option especially in people with diabetes with difficulty in post-prandial glycemic control.
Supplementary materials related to this article can be found online at https://doi.org/10.4093/dmj.2022.0035.
Supplementary Table 1.
Risk of bias assessment table
dmj-2022-0035-Supplementary-Table-1.pdf
Supplementary Fig. 1.
Flowchart elaborating on study retrieval and inclusion in the meta-analysis. Reason 1: lack of a valid control group [14]; Reason 2: was a virtual simulated study [15]; Reason 3: pramlintide was used along with fast-acting aspart insulin [16].
dmj-2022-0035-Supplementary-Fig-1.pdf
Supplementary Fig. 2.
Funnel plot of all the included studies in the meta-analysis (assessing the publication bias) of the main outcomes assessed (A) 1-hour post-prandial glucose, (B) 2-hour post-prandial glucose, (C) treatment-emergent adverse events, (D) total hypoglycamia episode, and (E) occlusion episodes. SE, standard error; MD, mean difference; OR, odds ratio.
dmj-2022-0035-Supplementary-Fig-2.pdf

CONFLICTS OF INTEREST

No potential conflict of interest relevant to this article was reported.

AUTHOR CONTRIBUTIONS

Conception or design: D.D., M.S.

Acquisition, analysis, or interpretation of data: R.M., K.M., M.S.

Drafting the work or revising: D.D., K.M., M.S.

Final approval of the manuscript: D.D., R.M., K.M., M.S.

FUNDING

None

Acknowledgements
None
Fig. 1.
(A) Risk of bias graph: review authors’ judgements about each risk of bias item presented as percentages across all included studies. (B) Risk of bias summary: review authors’ judgements about each risk of bias item for each included study.
dmj-2022-0035f1.jpg
Fig. 2.
Forest plot highlighting the impact of fast-acting aspart insulin (FIAsp) as compared to aspart insulin on (A) 1-hour postprandial glucose, (B) 2-hour post-prandial glucose, (C) total daily bolus insulin, and (D) total daily insulin requirement. SD, standard deviation; IV, inverse variance; CI, confidence interval.
dmj-2022-0035f2.jpg
Fig. 3.
Forest plot highlighting the impact of fast-acting aspart insulin (FIAsp) as compared to aspart insulin on (A) percent time in hypoglycaemia range (blood glucose <3.9 mmol/L), (B) time in range (blood glucose 3.9 to 10 mmol/L), (C) total hypoglycaemia episodes, and (D) severe hypoglycaemia episodes. SD, standard deviation; IV, inverse variance; CI, confidence interval; M-H, Mantel-Haenszel.
dmj-2022-0035f3.jpg
Fig. 4.
Forest plot highlighting the impact of fast-acting aspart insulin (FIAsp) as compared to aspart insulin on (A) treatment-emergent adverse events, (B) severe adverse events, (C) infusion site reactions, and (D) occlusion events. M-H, Mantel-Haenszel; CI, confidence interval.
dmj-2022-0035f4.jpg
Table 1.
Patients characteristics of the different randomised controlled trials evaluated in this meta-analysis
Characteristic Boughton et al. (2021) [11]a
Hsu et al. (2021) [13]a
Klonoff et al. (2019) [12]
Ozer et al. (2021) [5]a
Study/Control group (n=25) Study/Control group (n=19) Study group (n=236) Control group (n=236) Study/Control group (n=40)
Age, yr 38.0±9.0 40.4±17.7 43.3±14.8 43.6±14.7 45.7±12.93
Male sex, % 48.0 53.0 43.6 42.4 67.76
Participants 22.0±12.0 yr T1DMD 26.6±12.3 yr T1DMD 25±12.7 yr T1DMD 23.3±11.3 yr T1DMD Adults >18 yr; T1DMD >1 yr
Study duration, wk 8 2 16 16 7
Baseline HbA1c, % 7.4±0.8 7.1±0.54 7.5±0.5 7.5±0.5 7.0±0.54
BMI, kg/m2 26.0±4.3 NA 26.2±4.1 26.5±3.9 27.1±3.41

Values are presented as mean±standard deviation.

T1DMD, type 1 diabetes mellitus duration; HbA1c, glycosylated hemoglobin; BMI, body mass index; NA, not available.

a Cross-over study; hence only single group of patients acted both as the study and control group sequentially.

Table 2.
Summary of findings of the key outcomes of the study
Outcomes Anticipated absolute effectsa (95% CI)
Relative effect (95% CI) No. of participants (studies) Certainty of the evidence (GRADE)
Risk with control Risk with FIAsp
1-hr post-prandial glucose The mean 1h post-prandial glucose was 10.49 mmol/L MD 1.35 mmol/L lower (1.72 lower–0.98 lower) - 535 (2 RCTs) ⊕⊕⊕⊕
High
2-hr post-prandial glucose The mean 2h post-prandial glucose was 12.08 mmol/L MD 1.19 mmol/L lower (1.38 lower–1 lower) - 552 (2 RCTs) ⊕⊕⊕⊕
High
Treatment-emergent adverse events 550 per 1,000 580 per 1,000 (494–662) OR 1.13 (0.80–1.60) 640 (4 RCTs) ⊕⊕⊕⊖
Moderateb
Total hypoglycaemic episodes 786 per 1,000 833 per 1,000 (669–924) OR 1.35 (0.55–3.31) 590 (3 RCTs) ⊕⊕⊕⊕
High
Occlusion events 213 per 1,000 204 per 1,000 (149–276) OR 0.95 (0.65–1.41) 640 (4 RCTs) ⊕⊕⊕⊖
Moderateb

GRADE Working Group grades of evidence: High certainty (we are very confident that the true effect lies close to that of the estimate of the effect), Moderate certainty (we are moderately confident in the effect estimate: the true effect is likely to be close to the estimate of the effect, but there is a possibility that it is substantially different), Low certainty (our confidence in the effect estimate is limited: the true effect may be substantially different from the estimate of the effect), Very low certainty (we have very little confidence in the effect estimate: the true effect is likely to be substantially different from the estimate of effect).

CI, confidence interval; GRADE, Grades of Recommendation, Assessment, Development and Evaluation; FIAsp, fast-acting aspart insulin; MD, mean difference; RCT, randomised controlled trial; OR, odds ratio.

a The risk in the intervention group (and its 95% CI) is based on the assumed risk in the comparison group and the relative effect of the intervention (and its 95% CI),

b Funnel plot is suggestive of presence of most of the studies outside the plot; hence, it is likely that significant publication bias is present (Supplementary Fig. 2).

  • 1. Garg SK, Weinzimer SA, Tamborlane WV, Buckingham BA, Bode BW, Bailey TS, et al. Glucose outcomes with the in-home use of a hybrid closed-loop insulin delivery system in adolescents and adults with type 1 diabetes. Diabetes Technol Ther 2017;19:155-63.ArticlePubMedPMC
  • 2. Heise T, Pieber TR, Danne T, Erichsen L, Haahr H. A pooled analysis of clinical pharmacology trials investigating the pharmacokinetic and pharmacodynamic characteristics of fast-acting insulin aspart in adults with type 1 diabetes. Clin Pharmacokinet 2017;56:551-9.ArticlePubMedPMCPDF
  • 3. Heise T, Hovelmann U, Brondsted L, Adrian CL, Nosek L, Haahr H. Faster-acting insulin aspart: earlier onset of appearance and greater early pharmacokinetic and pharmacodynamic effects than insulin aspart. Diabetes Obes Metab 2015;17:682-8.ArticlePubMedPMCPDF
  • 4. Haahr H, Heise T. Fast-acting insulin aspart: a review of its pharmacokinetic and pharmacodynamic properties and the clinical consequences. Clin Pharmacokinet 2020;59:155-72.ArticlePubMedPMCPDF
  • 5. Ozer K, Cooper AM, Ahn LP, Waggonner CR, Blevins TC. Fast acting insulin aspart compared with insulin aspart in the Medtronic 670G hybrid closed loop system in type 1 diabetes: an open label crossover study. Diabetes Technol Ther 2021;23:286-92.ArticlePubMedPMC
  • 6. Higgins JP, Altman DG, Gotzsche PC, Juni P, Moher D, Oxman AD, et al. The Cochrane Collaboration’s tool for assessing risk of bias in randomised trials. BMJ 2011;343:d5928.ArticlePubMedPMC
  • 7. Dutta D, Bhattacharya S, Surana V, Aggarwal S, Singla R, Khandelwal D, et al. Efficacy and safety of saroglitazar in managing hypertriglyceridemia in type-2 diabetes: a meta-analysis. Diabetes Metab Syndr 2020;14:1759-68.ArticlePubMed
  • 8. Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gotzsche PC, Ioannidis JP, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. BMJ 2009;339:b2700.ArticlePubMedPMC
  • 9. Guyatt GH, Oxman AD, Vist GE, Kunz R, Falck-Ytter Y, Alonso-Coello P, et al. GRADE: an emerging consensus on rating quality of evidence and strength of recommendations. BMJ 2008;336:924-6.ArticlePubMedPMC
  • 10. Song F, Eastwood AJ, Gilbody S, Duley L, Sutton AJ. Publication and related biases. Health Technol Assess 2000;4:1-115.ArticlePMCPDF
  • 11. Boughton CK, Hartnell S, Thabit H, Poettler T, Herzig D, Wilinska ME, et al. Hybrid closed-loop glucose control with faster insulin aspart compared with standard insulin aspart in adults with type 1 diabetes: a double-blind, multicentre, multinational, randomized, crossover study. Diabetes Obes Metab 2021;23:1389-96.ArticlePubMedPDF
  • 12. Klonoff DC, Evans ML, Lane W, Kempe HP, Renard E, DeVries JH, et al. A randomized, multicentre trial evaluating the efficacy and safety of fast-acting insulin aspart in continuous subcutaneous insulin infusion in adults with type 1 diabetes (onset 5). Diabetes Obes Metab 2019;21:961-7.ArticlePubMedPMCPDF
  • 13. Hsu L, Buckingham B, Basina M, Ekhlaspour L, von Eyben R, Wang J, et al. Fast-acting insulin aspart use with the MiniMedTM 670G System. Diabetes Technol Ther 2021;23:1-7.ArticlePubMedPMC
  • 14. Russell SJ, Balliro C, Ekelund M, El-Khatib F, Graungaard T, Greaux E, et al. Improvements in glycemic control achieved by altering the tmax setting in the iLet® bionic pancreas when using fast-acting insulin aspart: a randomized trial. Diabetes Ther 2021;12:2019-33.ArticlePubMedPMCPDF
  • 15. Grosman B, Wu D, Parikh N, Roy A, Voskanyan G, Kurtz N, et al. Fast-acting insulin aspart (Fiasp®) improves glycemic outcomes when used with MiniMedTM 670G hybrid closed-loop system in simulated trials compared to NovoLog®. Comput Methods Programs Biomed 2021;205:106087.ArticlePubMed
  • 16. Tsoukas MA, Cohen E, Legault L, von Oettingen JE, Yale JF, Vallis M, et al. Alleviating carbohydrate counting with a FiASP-plus-pramlintide closed-loop delivery system (artificial pancreas): feasibility and pilot studies. Diabetes Obes Metab 2021;23:2090-8.PubMedPDF
  • 17. Avgerinos I, Papanastasiou G, Karagiannis T, Michailidis T, Liakos A, Mainou M, et al. Ultra-rapid-acting insulins for adults with diabetes: a systematic review and meta-analysis. Diabetes Obes Metab 2021;23:2395-401.ArticlePubMedPDF
  • 18. Rys P, Pankiewicz O, Lach K, Kwaskowski A, Skrzekowska-Baran I, Malecki MT. Efficacy and safety comparison of rapidacting insulin aspart and regular human insulin in the treatment of type 1 and type 2 diabetes mellitus: a systematic review. Diabetes Metab 2011;37:190-200.ArticlePubMed
  • 19. Evans M, Wilkinson M, Giannpolou A. Fast-acting insulin aspart: the rationale for a new mealtime insulin. Diabetes Ther 2019;10:1793-800.ArticlePubMedPMCPDF
  • 20. Evans M, Ceriello A, Danne T, De Block C, DeVries JH, Lind M, et al. Use of fast-acting insulin aspart in insulin pump therapy in clinical practice. Diabetes Obes Metab 2019;21:2039-47.ArticlePubMedPMCPDF
  • 21. 1MG: FIAsp insulin online purchase. Available from: https://www.1mg.com/drugs/fiasp-100iu-ml-penfill-506091 (cited 2022 Feb 14).
  • 22. 1MG: Novorapid insulin online purchase. Available from: https://www.1mg.com/drugs/novorapid-100iu-ml-solution-for-injection-372477 (cited 2022 Feb 14).
  • 23. 1MG: Aspart insulin online purchase. Available from: https://www.1mg.com/drugs/humalog-100iu-ml-solution-for-injection-341834 (cited 2022 Feb 14).
  • 24. Lee B. How much does insulin cost? Here’s how 28 brands and generics compare. Available from: https://www.goodrx.com/healthcare-access/research/how-much-does-insulin-cost-compare-brands (updated 2022 Jan 26).

Figure & Data

References

    Citations

    Citations to this article as recorded by  
    • Burden and Coping Strategies of Hypoglycemia in People with Diabetes
      Aris Liakos, Thomas Karagiannis, Ioannis Avgerinos, Apostolos Tsapas, Eleni Bekiari
      Current Diabetes Reviews.2024;[Epub]     CrossRef
    • Ultrafast-acting insulin: pharmacological properties and their impact on clinical aspects
      L. A. Suplotova, A. Sh. Tilkiyan
      Meditsinskiy sovet = Medical Council.2024; (13): 146.     CrossRef
    • Efficacy and Safety of Ultra-rapid Lispro Insulin in Managing Type-1 and Type-2 Diabetes: A Systematic Review and Meta-Analysis
      Deep Dutta, Lakshmi Nagendra, Saptarshi Bhattacharya, Meha Sharma
      Indian Journal of Endocrinology and Metabolism.2023; 27(6): 467.     CrossRef

    • PubReader PubReader
    • ePub LinkePub Link
    • Cite this Article
      Cite this Article
      export Copy Download
      Close
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      Performance of Fast-Acting Aspart Insulin as Compared to Aspart Insulin in Insulin Pump for Managing Type 1 Diabetes Mellitus: A Meta-Analysis
      Diabetes Metab J. 2023;47(1):72-81.   Published online June 24, 2022
      Close
    • XML DownloadXML Download
    Figure
    • 0
    • 1
    • 2
    • 3
    Performance of Fast-Acting Aspart Insulin as Compared to Aspart Insulin in Insulin Pump for Managing Type 1 Diabetes Mellitus: A Meta-Analysis
    Image Image Image Image
    Fig. 1. (A) Risk of bias graph: review authors’ judgements about each risk of bias item presented as percentages across all included studies. (B) Risk of bias summary: review authors’ judgements about each risk of bias item for each included study.
    Fig. 2. Forest plot highlighting the impact of fast-acting aspart insulin (FIAsp) as compared to aspart insulin on (A) 1-hour postprandial glucose, (B) 2-hour post-prandial glucose, (C) total daily bolus insulin, and (D) total daily insulin requirement. SD, standard deviation; IV, inverse variance; CI, confidence interval.
    Fig. 3. Forest plot highlighting the impact of fast-acting aspart insulin (FIAsp) as compared to aspart insulin on (A) percent time in hypoglycaemia range (blood glucose <3.9 mmol/L), (B) time in range (blood glucose 3.9 to 10 mmol/L), (C) total hypoglycaemia episodes, and (D) severe hypoglycaemia episodes. SD, standard deviation; IV, inverse variance; CI, confidence interval; M-H, Mantel-Haenszel.
    Fig. 4. Forest plot highlighting the impact of fast-acting aspart insulin (FIAsp) as compared to aspart insulin on (A) treatment-emergent adverse events, (B) severe adverse events, (C) infusion site reactions, and (D) occlusion events. M-H, Mantel-Haenszel; CI, confidence interval.
    Performance of Fast-Acting Aspart Insulin as Compared to Aspart Insulin in Insulin Pump for Managing Type 1 Diabetes Mellitus: A Meta-Analysis
    Characteristic Boughton et al. (2021) [11]a
    Hsu et al. (2021) [13]a
    Klonoff et al. (2019) [12]
    Ozer et al. (2021) [5]a
    Study/Control group (n=25) Study/Control group (n=19) Study group (n=236) Control group (n=236) Study/Control group (n=40)
    Age, yr 38.0±9.0 40.4±17.7 43.3±14.8 43.6±14.7 45.7±12.93
    Male sex, % 48.0 53.0 43.6 42.4 67.76
    Participants 22.0±12.0 yr T1DMD 26.6±12.3 yr T1DMD 25±12.7 yr T1DMD 23.3±11.3 yr T1DMD Adults >18 yr; T1DMD >1 yr
    Study duration, wk 8 2 16 16 7
    Baseline HbA1c, % 7.4±0.8 7.1±0.54 7.5±0.5 7.5±0.5 7.0±0.54
    BMI, kg/m2 26.0±4.3 NA 26.2±4.1 26.5±3.9 27.1±3.41
    Outcomes Anticipated absolute effectsa (95% CI)
    Relative effect (95% CI) No. of participants (studies) Certainty of the evidence (GRADE)
    Risk with control Risk with FIAsp
    1-hr post-prandial glucose The mean 1h post-prandial glucose was 10.49 mmol/L MD 1.35 mmol/L lower (1.72 lower–0.98 lower) - 535 (2 RCTs) ⊕⊕⊕⊕
    High
    2-hr post-prandial glucose The mean 2h post-prandial glucose was 12.08 mmol/L MD 1.19 mmol/L lower (1.38 lower–1 lower) - 552 (2 RCTs) ⊕⊕⊕⊕
    High
    Treatment-emergent adverse events 550 per 1,000 580 per 1,000 (494–662) OR 1.13 (0.80–1.60) 640 (4 RCTs) ⊕⊕⊕⊖
    Moderateb
    Total hypoglycaemic episodes 786 per 1,000 833 per 1,000 (669–924) OR 1.35 (0.55–3.31) 590 (3 RCTs) ⊕⊕⊕⊕
    High
    Occlusion events 213 per 1,000 204 per 1,000 (149–276) OR 0.95 (0.65–1.41) 640 (4 RCTs) ⊕⊕⊕⊖
    Moderateb
    Table 1. Patients characteristics of the different randomised controlled trials evaluated in this meta-analysis

    Values are presented as mean±standard deviation.

    T1DMD, type 1 diabetes mellitus duration; HbA1c, glycosylated hemoglobin; BMI, body mass index; NA, not available.

    Cross-over study; hence only single group of patients acted both as the study and control group sequentially.

    Table 2. Summary of findings of the key outcomes of the study

    GRADE Working Group grades of evidence: High certainty (we are very confident that the true effect lies close to that of the estimate of the effect), Moderate certainty (we are moderately confident in the effect estimate: the true effect is likely to be close to the estimate of the effect, but there is a possibility that it is substantially different), Low certainty (our confidence in the effect estimate is limited: the true effect may be substantially different from the estimate of the effect), Very low certainty (we have very little confidence in the effect estimate: the true effect is likely to be substantially different from the estimate of effect).

    CI, confidence interval; GRADE, Grades of Recommendation, Assessment, Development and Evaluation; FIAsp, fast-acting aspart insulin; MD, mean difference; RCT, randomised controlled trial; OR, odds ratio.

    The risk in the intervention group (and its 95% CI) is based on the assumed risk in the comparison group and the relative effect of the intervention (and its 95% CI),

    Funnel plot is suggestive of presence of most of the studies outside the plot; hence, it is likely that significant publication bias is present (Supplementary Fig. 2).

    Dutta D, Mohindra R, Mahajan K, Sharma M. Performance of Fast-Acting Aspart Insulin as Compared to Aspart Insulin in Insulin Pump for Managing Type 1 Diabetes Mellitus: A Meta-Analysis. Diabetes Metab J. 2023;47(1):72-81.
    Received: Feb 01, 2022; Accepted: Mar 15, 2022
    DOI: https://doi.org/10.4093/dmj.2022.0035.

    Diabetes Metab J : Diabetes & Metabolism Journal
    Close layer
    TOP