Skip Navigation
Skip to contents

Diabetes Metab J : Diabetes & Metabolism Journal

Search
OPEN ACCESS

Search

Page Path
HOME > Search
20 "Glucose monitoring"
Filter
Filter
Article category
Keywords
Publication year
Authors
Funded articles
Original Article
Type 1 Diabetes
Article image
Determinants of Discordance between Estimated and Measured HbA1c: The Role of Active Time in 14-Day Continuous Glucose Monitoring Data
Jee Hee Yoo, Seohyun Kim, Yeonsoo Park, Sang-Man Jin, Choon Hee Chung, Soo Heon Kwak, Jae Hyeon Kim, Gyuri Kim
Received November 19, 2025  Accepted March 17, 2026  Published online November 4, 2026  
DOI: https://doi.org/10.4093/dmj.2025.1170    [Epub ahead of print]
  • 357 View
  • 8 Download
AbstractAbstract PDF
Background
We aimed to investigate factors contributing to discordance between estimated glycosylated hemoglobin (eHbA1c) and measured HbA1c (mHbA1c) from continuous glucose monitoring (CGM) using both 14- and 90-day data in a large Asian cohort.
Methods
We retrospectively analyzed 3,724 14-day and 2,664 90-day glycemic profiles with ≥70% active CGM time (AT) from 1,028 individuals with type 1 diabetes mellitus (T1DM). eHbA1c was calculated using a regression model derived from our study population. Discordance was defined as eHbA1c–mHbA1c (overestimation [eHbA1c ≥ mHbA1c] or underestimation [eHbA1c < mHbA1c]). Similarity was defined as a difference within ±0.1%.
Results
The 14-day eHbA1c model explained 74.7% of the variance in mHbA1c, compared with 88.4% for the 90-day eHbA1c model (conditional R2). Absolute discordance was significantly lower in real-time CGM (rtCGM) than in intermittently scanned CGM (isCGM) (P=0.004), and in those with higher time in range (TIR) and AT (all P<0.001). Overestimation was associated with rtCGM (P=0.016) and lower HbA1c (P<0.001). Underestimation was greater in isCGM users and in those with higher HbA1c and lower body mass index (all P≤0.001). In 14-day profiles, ≥78% AT was required for eHbA1c–mHbA1c similarity, whereas 90-day profiles maintained similarity regardless of AT. A prediction model incorporating AT, TIR, and sensor type improved accuracy (R2: 14-day, 0.774; 90-day, 0.888), particularly for 14-day data.
Conclusion
Factors influencing eHbA1c–mHbA1c concordance differ by CGM duration. While 14-day data require higher AT (≥78%) for accuracy, 90-day data provide more stable estimates. Clinical interpretation must account for mHbA1c, TIR, and sensor type, especially when using shorter-term CGM profiles in Asian individuals with T1DM.
Reviews
Guideline/Statement/Fact Sheet
Article image
Clinical Implementation of Continuous Glucose Monitoring for Hospitalized Patients: A Position Statement of the Korean Diabetes Association Digital Health Committee
Jee Hee Yoo, Sun-Joon Moon, Da Young Lee, So Yoon Kwon, Kyuho Kim, Joonyub Lee, Yunjung Cho, Sungrae Kim, Jae-Seung Yun, Committee of Digital Health of the Korean Diabetes Association
Diabetes Metab J. 2026;50(6):1021-1043.   Published online November 1, 2026
DOI: https://doi.org/10.4093/dmj.2026.0923
  • 517 View
  • 33 Download
AbstractAbstract PDF
Continuous glucose monitoring (CGM) has emerged as a promising approach to improving glycemic management in hospitalized individuals. Evidence from inpatient studies supports the benefits of CGM in monitoring glucose trends and improving the detection of otherwise unrecognized hypoglycemic and hyperglycemic episodes. Improvements in glycemic control have also been reported with CGM-integrated management, although these benefits may depend on structured insulin titration protocols, confirmatory point-of-care testing, dedicated glycemic management teams, and institutional workflows. However, the inpatient setting presents unique challenges, including hemodynamic instability, surgical interventions, radiologic procedures, and potential drug interference, which may affect CGM accuracy and safety. Systematic guidelines for implementing CGM in inpatient care remain scarce internationally, highlighting the need for structured evidence synthesis and practical recommendations. In this position statement, the Korean Diabetes Association Digital Health Committee reviews current evidence on the efficacy and accuracy of CGM in inpatient settings and highlights key considerations for its safe implementation, including target populations, hybrid monitoring strategies, and procedural safety. We propose an operational framework for inpatient CGM use, aiming to establish a foundation for its systematic adoption and to inform future institutional and regulatory frameworks.
Technology/Device
Article image
Continuous Glucose Monitoring in Prediabetes and Early Dysglycemia: A Narrative Review
Gerald Gui Ren Sng, Suresh Rama Chandran, Daphne Gardner
Diabetes Metab J. 2026;50(6):1044-1057.   Published online November 1, 2026
DOI: https://doi.org/10.4093/dmj.2026.0776
  • 483 View
  • 28 Download
AbstractAbstract PDF
Early dysglycemia, including prediabetes, represents heterogeneous and dynamic states that are incompletely captured by fasting plasma glucose, glycosylated hemoglobin, or a single oral glucose tolerance test. Continuous glucose monitoring (CGM) provides a higher-density assessment of glucose behavior under free-living conditions, enabling characterization of fasting, postprandial, nocturnal and activity-related glucose patterns before the onset of diabetes. This narrative review summarizes current evidence on CGM in normoglycemia towards early dysglycemia, with emphasis on conventional CGM metrics, higher-order features derived from raw glucose time series, and emerging artificial intelligence approaches. Existing studies show that individuals with prediabetes have higher mean glucose, greater time above tight glucose ranges, lower time in tight range and greater glycemic variability than normoglycemic comparators. However, absolute differences are small, and distributions overlap substantially. More recent approaches, including the concept of glucotypes, multi-feature classifiers, personalized postprandial response models, glucodensity methods and glucose foundation models, suggest that CGM may capture richer temporal and individualized phenotypes than consensus summary metrics alone, supporting future risk stratification, mechanistic subphenotyping and targeted prevention. However, model validation remains limited, and outcome-linked CGM thresholds are not yet established. At present, CGM should still be viewed as a promising research and phenotyping tool in early dysglycemia.
Original Articles
Technology/Device
Article image
Association between Continuous Glucose Monitoring and Risk of Acute Diabetes-Related Complications in Pediatric Type 1 Diabetes Mellitus: A Nationwide Cohort Study
Ji Yoon Kim, Seohyun Kim, Jae Hyeon Kim
Received August 21, 2025  Accepted February 3, 2026  Published online April 22, 2026  
DOI: https://doi.org/10.4093/dmj.2025.0794    [Epub ahead of print]
  • 3,745 View
  • 108 Download
  • 2 Crossref
AbstractAbstract PDFSupplementary MaterialPubReader   ePub   
Background
Evidence supporting the benefits of continuous glucose monitoring (CGM) in reducing diabetes-related complications remains scarce. This study aimed to investigate the association between CGM and diabetes-related complications, specifically diabetic ketoacidosis (DKA) and severe hypoglycemia in children and adolescents with type 1 diabetes mellitus (T1DM).
Methods
From the Korean Nationwide Cohort (2016–2022), we included children and adolescents (aged <19 years) with T1DM who received rapid-acting insulin between 2019 and 2022. The primary outcomes were DKA and severe hypoglycemia. Adjusted hazard ratios (HRs) for the primary outcomes were compared between CGM users and non-users using Cox proportional hazards regression models. Additionally, among the CGM users, the frequencies of DKA and severe hypoglycemia were compared before and after CGM initiation using a paired t-test.
Results
This study included 3,765 children and adolescents (2,313 CGM users and 1,452 non-users). During a median follow-up of 2.7 years, CGM users showed a lower risk of DKA (adjusted HR, 0.44; 95% confidence interval [CI], 0.35 to 0.56) and severe hypoglycemia (adjusted HR, 0.48; 95% CI, 0.29 to 0.79) than non-users. Among CGM users, the mean frequency of DKA decreased by 64%, and that of severe hypoglycemia decreased by 57% after CGM initiation (P<0.001 for both).
Conclusion
In this nationwide cohort study, CGM was associated with a reduced risk of DKA and severe hypoglycemia in children and adolescents with T1DM.

Citations

Citations to this article as recorded by  
  • Association between Continuous Glucose Monitoring and Risk of Acute Diabetes-Related Complications in Pediatric Type 1 Diabetes Mellitus: A Nationwide Cohort Study (Diabetes Metab J 2026 Apr 22 [Epub]. https://doi.org/10.4093/dmj.2025.0794)
    Junfeng Yuan
    Diabetes & Metabolism Journal.2026;[Epub]     CrossRef
  • Association between Continuous Glucose Monitoring and Risk of Acute Diabetes-Related Complications in Pediatric Type 1 Diabetes Mellitus: A Nationwide Cohort Study (Diabetes Metab J 2026 Apr 22 [Epub]. https://doi.org/10.4093/dmj.2025.0794)
    Ji Yoon Kim, Seohyun Kim, Jae Hyeon Kim
    Diabetes & Metabolism Journal.2026;[Epub]     CrossRef
Lifestyle and Behavioral Interventions
Article image
Influence of Fibroblast Growth Factor 21 on Delayed Glycemic Improvement Following Acute Exercise in Type 2 Diabetes Mellitus
Ying Zhang, Dan Liu, Yurun Lu, Piao Kang, Xinyu Liu, Qinyi Wang, Anran Chen, Di Cheng, Liang Wu, Qi Li, Xiaolin Wang, Yanli Li, Yaorui Ye, Jingyi Yang, Jiacheng Ni, Qichen Fang, Zhe Huang, Aimin Xu, Weiping Jia, Yong Wang, Guowang Xu, Huating Li
Diabetes Metab J. 2026;50(4):770-784.   Published online March 25, 2026
DOI: https://doi.org/10.4093/dmj.2024.0814
  • 5,180 View
  • 89 Download
  • 1 Crossref
AbstractAbstract PDFSupplementary MaterialPubReader   ePub   
Background
Exercise positively influences glycemic control. Some individuals experience greater glycemic stability on the day after exercise, even without additional physical activity. However, the mechanisms underlying this delayed glycemic improvement remain unclear.
Methods
Seventy-one patients with type 2 diabetes mellitus were assigned to either a 60-minute exercise group or a resting group. Serum fibroblast growth factor 21 (FGF21) levels and untargeted metabolomic profiles were assessed at multiple time points before and after exercise. Interstitial glucose levels were monitored using continuous glucose monitoring system. FGF21 knockout mice and wild-type littermates fed a high-fat diet underwent a 3-week exercise intervention and received FGF21 supplementation.
Results
Individuals exhibiting delayed glycemic improvement (responders) displayed a significantly stronger FGF21 response than non-responders. Baseline metabolites, including p-cresol sulfate and dimethylglycine, differed between responders and non-responders and were associated with the FGF21 response. Longitudinal time-series analyses revealed post-exercise differences in acylcarnitines, fatty acids, and complex lipids between responders and non-responders. Dynamic correlation and mediation analyses supported the role of FGF21 in modulating delayed glycemic improvement through regulation of lipid metabolism. In vivo FGF21 knockout and rescue experiments demonstrated that FGF21 is necessary for these metabolic shifts and the associated improvements in glucose tolerance and insulin sensitivity.
Conclusion
This study suggests that the baseline metabolome is associated with the magnitude of the post-exercise FGF21 response, which influences delayed glycemic improvement through regulation of lipid metabolism pathways.

Citations

Citations to this article as recorded by  
  • Fibroblast Growth Factor 21: Bridging Nutrient Stress Signaling and Exercise-Induced Adaptive Responses
    Dae Ho Lee
    Diabetes & Metabolism Journal.2026; 50(4): 669.     CrossRef
Brief Report
Technology/Device
Article image
Effectiveness of the Stage 4 Smart Insulin Pen DIA:CONN P8 for Glycemic Control in a Real-World Setting
So Yoon Kwon, Hyoseon Kwak, Jae Hyeon Kim
Diabetes Metab J. 2026;50(3):612-617.   Published online September 3, 2025
DOI: https://doi.org/10.4093/dmj.2025.0112
  • 5,249 View
  • 171 Download
  • 3 Web of Science
  • 3 Crossref
AbstractAbstract PDFSupplementary MaterialPubReader   ePub   
This study evaluated whether a stage 4 smart insulin pen (SIP) provides superior glycemic control compared with a traditional insulin pen (TIP) in individuals with intensively insulin-treated diabetes. Forty-two adults with continuous glucose monitoring (CGM), multiple daily insulin injections, and no prior SIP use were included. After diabetes self-management education (DSME), the SIP group (n=21) initiated SIP, whereas the TIP group (n=21) continued their usual regimens. Glycemic metrics were assessed using CGM before and 2 weeks after DSME. Both groups demonstrated significant improvements in glycemic outcomes. However, SIP users exhibited superior improvements in the percentage of time in range, percentage of time below range (%TBR) <70 mg/dL, %TBR <54 mg/dL, and glycemic risk index compared with TIP users (between-group difference [BD] 11.0%, P=0.046; BD –2.6%, P=0.024; BD –0.9%, P=0.027; BD –18.2, P=0.022, respectively). These findings suggest that SIP, with its bolus calculation and CGM integration, is associated with improved glycemic outcomes in adults with intensively insulin-treated diabetes.

Citations

Citations to this article as recorded by  
  • Technology in Diabetes: A Year in Review
    Subhankar Chatterjee, Subhodip Pramanik, Nitin Kapoor, Sanjay Kalra
    Diabetes Therapy.2026; 17(6): 823.     CrossRef
  • Retrospective Validation of a Stage 5 Decision Support Algorithm Using Clinical Trial Data From Stage 4 Smart Insulin Pens
    Jee Hee Yoo, Seohyun Kim, Younghoon Kim, Sang-Man Jin, Jae Hyeon Kim
    Journal of Diabetes Science and Technology.2026;[Epub]     CrossRef
  • Insulin pens and the digital ecosystem
    Johan Jendle, Peter Adolfsson, Roque Cardona-Hernandez, Laurent Crenier, Sergio Di Molfetta, Dominic Ehrmann, Francesco Giorgino, Martin Haluzik, Irl B. Hirsch, Concetta Irace, Amy Jolley, David C. Klonoff, Jens Kröger, Julia K. Mader, Kirsten Nørgaard, J
    Diabetologia.2026; 69(12): 3449.     CrossRef
Original Articles
Pharmacotherapy
Article image
Glycemic Benefit of Insulin Degludec/Insulin Aspart Compared to Basal Insulin in Type 2 Diabetes Mellitus Associated with Impaired Glucagon-Like Peptide-1 Response: A Randomized Crossover Trial
Han Na Jang, Eun Shil Hong, Ye Seul Yang, Seong Ok Lee, Myoung-jin Jang, Andrea Mari, Soo Heon Kwak, Kyong Soo Park, Hak Chul Jang, Hye Seung Jung
Diabetes Metab J. 2026;50(3):552-564.   Published online August 14, 2025
DOI: https://doi.org/10.4093/dmj.2024.0741
  • 5,940 View
  • 159 Download
AbstractAbstract PDFSupplementary MaterialPubReader   ePub   
Background
We aimed to confirm that once-daily insulin degludec/insulin aspart (IDegAsp) is superior to basal insulin therapy in participants with type 2 diabetes mellitus (T2DM) exhibiting signs of overbasalization. Additionally, we analyzed incretin profiles in relation to the benefits of IDegAsp, providing insights into the underlying mechanisms.
Methods
A prospective study was conducted in participants receiving basal insulin therapy, with a fasting plasma glucose (FPG) level lower than predicted from their glycosylated hemoglobin (HbA1c). Participants were randomly assigned to either IDegAsp or insulin glargine (IGlar) in a 1:1 ratio. After 20 weeks of treatment, the insulins were switched in a crossover design. The primary endpoint was the change in HbA1c from baseline. Incretin profiles, hypoglycemic events, and continuous glucose monitoring (CGM) were also analyzed (Trial registration: www.cris.nih.go.kr; KCT0004597).
Results
The study included 55 participants (male 40%, mean age 65 years, FPG 103 mg/dL, and HbA1c 8.3%). HbA1c significantly decreased to 7.8%±0.8% with IDegAsp, compared to 8.0%±0.7% with IGlar. The mean estimated treatment difference of changes was –0.21% points (95% confidence interval, –0.39 to –0.02; P=0.031), favoring IDegAsp. Hypoglycemic events were comparable. CGM demonstrated significantly lower glucose measures during the daytime with IDegAsp compared to IGlar, and vice versa at dawn. The HbA1c benefit of IDegAsp over IGlar was associated with a low glucagon-like peptide-1 (GLP-1) ratio at 30 minutes relative to baseline (r=0.301, P=0.040), while not with glucose-dependent insulinotropic polypeptide.
Conclusion
The greater reduction in HbA1c achieved with IDegAsp compared to IGlar in individuals with T2DM was associated with an impaired GLP-1 response, facilitating personalized insulin therapy.
Technology/Device
Article image
First Trimester Mean Glucose Level on Continuous Glucose Monitoring Is Associated with Infant Birth Weight
Phaik Ling Quah, Lay Kok Tan, Serene Pei Ting Thain, Ngee Lek, Shephali Tagore, Bernard Su Min Chern, Seng Bin Ang, Ann Wright, Michelle Jong, Kok Hian Tan
Diabetes Metab J. 2025;49(6):1262-1271.   Published online June 2, 2025
DOI: https://doi.org/10.4093/dmj.2024.0700
  • 7,360 View
  • 126 Download
  • 3 Web of Science
  • 2 Crossref
AbstractAbstract PDFSupplementary MaterialPubReader   ePub   
Background
Comparisons between continuous glucose monitoring (CGM) metrics during the first and second trimesters and conventional mid-pregnancy oral glucose tolerance test (OGTT) values in pregnant women without pre-existing diabetes for predicting infant birth weight are scarce.
Methods
In a longitudinal observational study, 113 participants had first and second trimester CGM data collected over a 7- to 14-day period, as well as three-point OGTT (fasting, 1-hour, and 2-hour) performed at mid-pregnancy (24 to 28 weeks). Multinomial logistic regression, adjusting for maternal ethnicity, education level, age, pre-pregnancy body mass index, parity, gestational diabetes mellitus diagnosis, gestational age at delivery, and type of CGM sensor was used to analyse the relationship between CGM metrics, OGTT glucose values and infant birth weight tertile (Clinical trial identification number: NCT05123248).
Results
In the univariate analysis, CGM-derived metrics including higher mean glucose in the first trimester, higher % time above range in the second trimester, and higher % time in range (TIR) and lower % time below range (TBR) in both the first and second trimesters were associated with infants in the highest birth weight tertile. After adjusting for confounders, a 1-standard deviation increase in mean glucose level during the first trimester was significantly associated with the likelihood of the neonatal birthweight being in the highest tertile (adjusted odds ratio, 3.11; 95% confidence interval, 1.18 to 8.21; P=0.022). No significant associations were found between OGTT glucose values and infant birth weight outcomes.
Conclusion
CGM-derived mean glucose levels in early pregnancy may be a better predictor of an infant’s birth weight within the highest tertile, compared to mid-pregnancy OGTT glucose values.

Citations

Citations to this article as recorded by  
  • Maternal obesity and the metabolic syndrome in reproductive health: assessing incretin-based interventions
    Luisa Wallentowitz, Mariana G Garcia, Catalina Atorrasagasti, Charlotte Harms, Evelyn A Huhn, Pia Roser, Stefan Verlohren, Emma M Giesen, Sandra M Blois
    Reviews in Endocrine and Metabolic Disorders.2026; 27(4): 853.     CrossRef
  • Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes: Outcomes of a Population-Based Real-World Study
    Sarah A.L. Price, Melissa Chee, Arul Earnest, Rebecca L. Thomson, Megan A.S. Penno, Jennifer J. Couper, Jane Holmes-Walker, Stephanie Johnson, Glynis Ross, Arianne Sweeting, David Simmons, Sarah Glastras, Alexis Shub, Katherine Griffin, Dorothy Graham, An
    Diabetes Technology & Therapeutics.2026;[Epub]     CrossRef
Technology/Device
Article image
Current Status of Continuous Glucose Monitoring Use in South Korean Type 1 Diabetes Mellitus Population–Pronounced Age-Related Disparities: Nationwide Cohort Study
Ji Yoon Kim, Seohyun Kim, Jae Hyeon Kim
Diabetes Metab J. 2025;49(5):1040-1050.   Published online April 28, 2025
DOI: https://doi.org/10.4093/dmj.2024.0804
  • 10,491 View
  • 287 Download
  • 14 Web of Science
  • 16 Crossref
AbstractAbstract PDFSupplementary MaterialPubReader   ePub   
Background
This study aims to identify the status of continuous glucose monitoring (CGM) use among individuals with type 1 diabetes mellitus (T1DM) in South Korea and to investigate whether age-related disparities exist.
Methods
Individuals with T1DM receiving intensive insulin therapy were identified from the Korean National Health Insurance Cohort (2019–2022). Characteristics of CGM users and non-users were compared, and the prescription rates of CGM and sensor- augmented pump (SAP) or automated insulin delivery (AID) systems according to age groups (<19, 19–39, 40–59, and ≥60 years) were analyzed using chi-square tests. Glycosylated hemoglobin (HbA1c) levels and coefficients of variation (CV) among CGM users were also examined.
Results
Among the 56,908 individuals with T1DM, 10,822 (19.0%) used CGM at least once, and 6,073 (10.7%) used CGM continuously. Only 241 (0.4%) individuals utilized either SAP or AID systems. CGM users were younger than non-users. The continuous prescription rate of CGM was highest among individuals aged <19 years (37.0%), followed by those aged 19–39 years (15.8%), 40–59 years (10.7%), and ≥60 years (3.9%) (P<0.001 for between-group differences). Among CGM users, HbA1c levels decreased from 8.7%±2.4% at baseline to 7.2%±1.2% at 24 months, and CV decreased from 36.6%±11.9% at 3 months to 34.1%±12.7% at 24 months.
Conclusion
Despite national reimbursement for CGM devices, the prescription rates of CGM remain low, particularly among older adults. Given the improvements in HbA1c and CV following CGM initiation, more efforts are needed to increase CGM utilization and reduce age-related disparities.

Citations

Citations to this article as recorded by  
  • Efficacy and Safety of Stage 5 Connected Insulin Pens in Type 1 or Type 2 Diabetes: Randomized Controlled Trial Protocol (SMART-5 Study)
    Ji Yoon Kim, Nam Hoon Kim, Soo Heon Kwak, Chang Hee Jung, Eun Seok Kang, Jun Sung Moon, Sun Joon Moon, So Yoon Kwon, Jee Hee Yoo, Younghoon Kim, Tae-min Lee, Chung-il Yang, Jae Hyeon Kim, Sang-Man Jin
    Endocrinology and Metabolism.2026; 41(3): 393.     CrossRef
  • Association of perceived diabetes stigma with time below range <3.0 mmol/L and anxiety in adults with type 1 diabetes using continuous glucose monitoring
    Seohyun Kim, Soojin Park, Sang‐Man Jin, Jae Hyeon Kim, Gyuri Kim
    Diabetic Medicine.2026;[Epub]     CrossRef
  • Suboptimal adoption of diabetes technology despite coverage and the impact on glycemic outcomes in children and adolescents with type 1 diabetes in Hong Kong
    Sarah Wing-yiu Poon, Kwong-tat Chan, Betty Wai-man But, Shirley Man-yee Wong, Wing-in Yam, Pik-to Cheung, Wing-shan See, Suk-yan Chan, Ho-chung Yau, Eunice Wai Yu Wong, Lap Ming Wong, Antony Chun-cheung Fu, Elaine Yin-wah Kwan, Janez Heung-ching Tsui, Sin
    Journal of Pediatric Endocrinology and Metabolism.2026; 39(3): 251.     CrossRef
  • Preliminary clinical outcomes and adoption of continuous glucose monitoring following reimbursement implementation in patients with type 1 diabetes in Thailand
    Nichapa Yordsudueam, Nattakarn Numsriskulrat, Worapimon Lerdrassameethad, Pattayarporn Paleekul, Jutipond jitchana, Nitchakarn Laichuthai, Taninee Sahakitrungruang
    Annals of Pediatric Endocrinology & Metabolism.2026; 31(1): 66.     CrossRef
  • Challenges and Opportunities for Improving Care for Type 1 Diabetes in Older Adulthood
    Anna R. Kahkoska, Joshua J. Neumiller, Anastasia-Stefania Alexopoulos, Amlan Barik, Elbert S. Huang, Lori M. Laffel, Naushira Pandya, Christine Slyne, Elena Toschi, Ruth S. Weinstock, Medha Munshi
    Diabetes Care.2026; 49(4): 559.     CrossRef
  • Continuous glucose monitoring and risks of acute and chronic diabetes-related complications and mortality in adults with type 1 diabetes: a nationwide cohort study
    Ji Yoon Kim, Seohyun Kim, Jae Hyeon Kim
    Diabetologia.2026; 69(7): 1858.     CrossRef
  • Integrating Pharmacists into CGM-Enabled Digital Diabetes Care: Advancing Personalized and Data-Driven Management
    Xiaoxiao Chen, Gyeong Eon Kim, Nam Ah Kim, Kwang Joon Kim
    Healthcare.2026; 14(8): 1019.     CrossRef
  • Temporal trends in treatment-requiring microvascular complications in young-onset diabetes: A nationwide population-based study
    Hwa Young Kim, Eunjeong Ji, Jaehyun Kim
    Diabetes Research and Clinical Practice.2026; 238: 113349.     CrossRef
  • The National Health Insurance Support System for Diabetes Consumables and Management Devices in South Korea: Status, Challenges, and Policy Directions
    Okha Ryu, Yo Han Lee
    Health Insurance Review & Assessment Service Research.2026; 6(1): 46.     CrossRef
  • High Waist-to-Height Ratio Increases the Risk of Cardiovascular Outcomes in Adults with Type 1 Diabetes Mellitus: A Nationwide Cohort Study
    Kyeong-Jin Kim, Seohyun Kim, Rosa Oh, So Hyun Cho, Myunghwa Jang, You-Bin Lee, Gyuri Kim, Sang-Man Jin, Kyu Yeon Hur, Ji Yoon Kim, Jae Hyeon Kim
    Diabetes & Metabolism Journal.2026; 50(4): 739.     CrossRef
  • Trends of insulin pump therapy and continuous glucose monitoring use among people with type 1 diabetes by institution and region in Japan during 2014 and 2022: an observational study using nationwide claims data
    Takuya Yamaoka, Takehiro Sugiyama, Kimikazu Kashiwagi, Takashi Furuno, Kouko Yamamoto, Kenjiro Imai, Noriko Ihana-Sugiyama, Yuichi Nishioka, Mitsuru Ohsugi, Kohjiro Ueki, Akira Shimada, Toshimasa Yamauchi
    Diabetes Research and Clinical Practice.2026; 239: 113462.     CrossRef
  • Retrospective Validation of a Stage 5 Decision Support Algorithm Using Clinical Trial Data From Stage 4 Smart Insulin Pens
    Jee Hee Yoo, Seohyun Kim, Younghoon Kim, Sang-Man Jin, Jae Hyeon Kim
    Journal of Diabetes Science and Technology.2026;[Epub]     CrossRef
  • Utilization and Impact of Diabetes Technology among Type 1 Diabetes Patients at a Tertiary Hospital in Thailand
    Jirawan Pongrujikorn , Jutipond Jitchana, Nitchakarn Laichuthai
    Journal of the ASEAN Federation of Endocrine Societies.2026;[Epub]     CrossRef
  • Time in Range as a Marker of Concurrent Glycemic and Lipid Improvement in Adults with Type 2 Diabetes: A Real-World Retrospective Pre–Post Study
    Mi-Joon Lee, Bum-Jeun Seo, Jae-Hyoung Cho
    Life.2026; 16(10): 1667.     CrossRef
  • Three-Year Glycemic Trajectories in Subgroups With Type 1 Diabetes at Risk for Suboptimal Glycemic Control: A Multicenter Continuous Glucose Monitoring Study
    Jee Hee Yoo, Seohyun Kim, Yeonsoo Park, Soojin Park, Choon Hee Chung, Jae Hyeon Kim, Soo Heon Kwak, Gyuri Kim
    Diabetes Care.2026; 49(11): 2013.     CrossRef
  • Sequential use of continuous glucose monitoring, with or without exercise trackers, significantly improves glycemic control in patients with type 2 diabetes
    Anushka Lahiri, Suan Tee Lim, Htike Kyu, Yock Young Dan, Chin Meng Khoo
    Diabetology & Metabolic Syndrome.2025;[Epub]     CrossRef
Technology/Device
Article image
Comparison of Real-Time and Intermittently-Scanned Continuous Glucose Monitoring for Glycemic Control in Type 1 Diabetes Mellitus: Nationwide Cohort Study
Ji Yoon Kim, Seohyun Kim, Jae Hyeon Kim
Diabetes Metab J. 2025;49(3):436-447.   Published online February 27, 2025
DOI: https://doi.org/10.4093/dmj.2024.0160
  • 12,132 View
  • 276 Download
  • 9 Web of Science
  • 12 Crossref
AbstractAbstract PDFSupplementary MaterialPubReader   ePub   
Background
This study compares the association between real-time continuous glucose monitoring (rtCGM) and intermittently- scanned CGM (isCGM) and glycemic control in individuals with type 1 diabetes mellitus (T1DM) in a real-world setting.
Methods
Using data from the Korean National Health Insurance Service Cohort, individuals with T1DM managed by intensive insulin therapy were followed at 3-month intervals for 2 years after the initiation of CGM. The glycosylated hemoglobin (HbA1c) levels and coefficients of variation (CVs) of rtCGM and isCGM users were compared using independent two-sample t-test and a linear mixed model.
Results
The analyses considered 7,786 individuals (5,875 adults aged ≥19 years and 1,911 children and adolescents aged <19 years). Overall, a significant reduction in HbA1c level was observed after 3 months of CGM, and the effect was sustained for 2 years. The mean HbA1c level at baseline was higher in rtCGM users than in isCGM users (8.9%±2.7% vs. 8.6%±2.2%, P<0.001). However, from 3 to 24 months, rtCGM users had lower HbA1c levels than isCGM users at every time point (7.1%±1.2% vs. 7.5%±1.3% at 24 months, P<0.001 for all time points). In both adults and children, the greater reduction in HbA1c with rtCGM remained significant after adjusting for the baseline characteristics of the users. The CV also showed greater decrease with rtCGM than with isCGM.
Conclusion
In this large nationwide cohort study, the use of rtCGM was associated with a greater improvement in glycemic control, including HbA1c reduction, than the use of isCGM in both adults and children with T1DM.

Citations

Citations to this article as recorded by  
  • Efficacy and Safety of Stage 5 Connected Insulin Pens in Type 1 or Type 2 Diabetes: Randomized Controlled Trial Protocol (SMART-5 Study)
    Ji Yoon Kim, Nam Hoon Kim, Soo Heon Kwak, Chang Hee Jung, Eun Seok Kang, Jun Sung Moon, Sun Joon Moon, So Yoon Kwon, Jee Hee Yoo, Younghoon Kim, Tae-min Lee, Chung-il Yang, Jae Hyeon Kim, Sang-Man Jin
    Endocrinology and Metabolism.2026; 41(3): 393.     CrossRef
  • EMERGING DIGITAL TECHNOLOGIES IN MONITORING ENDOCRINE DISORDERS: CONTINUOUS GLUCOSE MONITORING SYSTEMS AND ARTIFICIAL INTELLIGENCE IN THE DIAGNOSIS OF POLYCYSTIC OVARY SYNDROME
    Aleksandra Ćwirko-Godycka, Nikola Murawska, Michalina Chodór, Aleksandra Tomaszewska, Kinga Karczewska, Sonia Mojzyk, Maciej Kokoszka, Aleksandra Mierniczek, Natalia Dymel, Ryszard Feret
    International Journal of Innovative Technologies in Social Science.2026;[Epub]     CrossRef
  • Dementia Risk in Type 1 and 2 Diabetes: A Nationwide Population‐Based Comparison
    Ji Eun Jun, Seohyun Kim, In‐Kyung Jeong, Jae Hyeon Kim
    Diabetes, Obesity and Metabolism.2026; 28(6): 4915.     CrossRef
  • Continuous glucose monitoring and risks of acute and chronic diabetes-related complications and mortality in adults with type 1 diabetes: a nationwide cohort study
    Ji Yoon Kim, Seohyun Kim, Jae Hyeon Kim
    Diabetologia.2026; 69(7): 1858.     CrossRef
  • Consensus-Based Recommendations on an Optimal Educational Pathway for Diabetes Educators for Training People With Diabetes on Continuous Glucose Monitoring in Saudi Arabia
    Ayman Al Hayek, Abeer Ali Yahya Aljabir, Abdulrahim Alsufyani, Alhanouf Alharthi, Amani Aldhewaila, Fatima Alawami, Hanan Kaki, Khulud Ali Alatawi, Mashael Mohammad Alfotais, Naglaa Helmy
    Journal of Diabetes Science and Technology.2026;[Epub]     CrossRef
  • Managing Gestational Diabetes Complexity with Continuous Glucose Monitoring: A Narrative Review
    Anca-Elena Crăciun, Dana Mihaela Ciobanu, Georgeta Inceu, Camelia Larisa Vonica, Denisa Herman, Cristian-Ioan Crăciun, Adriana Fodor, Cornelia Bala, Adriana Rusu
    Diagnostics.2026; 16(14): 2145.     CrossRef
  • ADJUNCT THERAPIES IN TYPE 1 DIABETES: A REVIEW OF MECHANISMS, MANAGEMENT AND SAFETY OF NEW FORMS OF TREATMENT
    Magda Downar-Zapolska, Agnieszka Mikłaszewicz, Aleksandra Irena Skuza, Emilia Torbacka, Katarzyna Helena Sergiel, Daniel Sagan, Dominik Fidorowicz, Marta Góral, Rafał Siedlecki, Katarzyna Bednarczuk
    International Journal of Innovative Technologies in Social Science.2026;[Epub]     CrossRef
  • Continuous Glucose Monitoring Alert Settings and Glycemic Control in People With Diabetes
    Yaguang Zheng, Stephen B. Johnson, Eduardo Iturrate, Bei Wu, Heng Huang, William Small, Susan Zweig, Rozalina G. McCoy
    JAMA Network Open.2026; 9(9): e2635687.     CrossRef
  • Beneficial Analysis for Glucose Variability by Continuous Glucose Monitoring (CGM)
    Sanae Mima, Hiroshi Bando, Akemi Tamura, Yukari Okino, Takumi Yamada, Yoshiyuki Abe
    Asploro Journal of Biomedical and Clinical Case Reports.2025; 8(2): 193.     CrossRef
  • Islet Tissue Macrophages in Immunity Homeostasis and Type 1 Diabetes
    Yan Wang, Zhaoran Wang, Wenya Diao, Tong Shi, Jiahe Xu, Tiantian Deng, Chaoying Wen, Jienan Gu, Tingting Deng, Sixuan Wang, Cheng Xiao
    Clinical Reviews in Allergy & Immunology.2025;[Epub]     CrossRef
  • Continuous glucose monitoring in Korean pediatric patients with type 1 diabetes: current landscape and clinical implications
    Hwa Young Kim, Jaehyun Kim
    Clinical and Experimental Pediatrics.2025; 68(11): 842.     CrossRef
  • Dispositivi indossabili per la gestione del diabete
    Filippo CARLUCCI, Antonella TABUCCHI, Marcello FIORINI, Lucrezia GALASSO, Alessandro TERRENI
    Biochimica Clinica.2025;[Epub]     CrossRef
Brief Report
Technology/Device
Article image
Effectiveness of Predicted Low-Glucose Suspend Pump Technology in the Prevention of Hypoglycemia in People with Type 1 Diabetes Mellitus: Real-World Data Using DIA:CONN G8
Jee Hee Yoo, Ji Yoon Kim, Jae Hyeon Kim
Diabetes Metab J. 2025;49(1):144-149.   Published online August 28, 2024
DOI: https://doi.org/10.4093/dmj.2024.0039
  • 9,786 View
  • 206 Download
  • 2 Web of Science
  • 3 Crossref
AbstractAbstract PDFSupplementary MaterialPubReader   ePub   
We evaluated the effectiveness of the predictive low-glucose suspend (PLGS) algorithm in the DIA:CONN G8. Forty people with type 1 diabetes mellitus (T1DM) who used a DIA:CONN G8 for at least 2 months with prior experience using pumps without and with PLGS were retrospectively analyzed. The objective was to assess the changes in time spent in hypoglycemia (percent of time below range [%TBR]) before and after using PLGS. The mean age, sensor glucose levels, glucose threshold for suspension, and suspension time were 31.1±22.8 years, 159.7±23.2 mg/dL, 81.1±9.1 mg/dL, and 111.9±79.8 min/day, respectively. Overnight %TBR <70 mg/dL was significantly reduced after using the algorithm (differences=0.3%, from 1.4%±1.5% to 1.1%±1.2%, P=0.045). The glycemia risk index (GRI) improved significantly by 4.2 (from 38.8±20.9 to 34.6±19.0, P=0.002). Using the PLGS did not result in a change in the hyperglycemia metric (all P>0.05). Our findings support the PLGS in DIA:CONN G8 as an effective algorithm to improve night-time hypoglycemia and GRI in people with T1DM.

Citations

Citations to this article as recorded by  
  • Scoping review of subcutaneous glucose monitoring techniques
    Eva Hrubá, Jan Kubíček, Martin Augustynek
    Measurement.2026; 261: 119940.     CrossRef
  • Assessment and Prevention of Hypoglycemia with Continuous Glucose Monitoring and Automated Insulin Delivery Systems
    Jee Hee Yoo
    The Journal of Korean Diabetes.2026; 27(3): 137.     CrossRef
  • Current Status of Continuous Glucose Monitoring Use in South Korean Type 1 Diabetes Mellitus Population–Pronounced Age-Related Disparities: Nationwide Cohort Study
    Ji Yoon Kim, Seohyun Kim, Jae Hyeon Kim
    Diabetes & Metabolism Journal.2025; 49(5): 1040.     CrossRef
Review
Clinical Diabetes & Therapeutics
Recent Updates on Type 1 Diabetes Mellitus Management for Clinicians
Ahmed Iqbal, Peter Novodvorsky, Simon R. Heller
Diabetes Metab J. 2018;42(1):3-18.   Published online February 23, 2018
DOI: https://doi.org/10.4093/dmj.2018.42.1.3
  • 15,906 View
  • 123 Download
  • 22 Web of Science
  • 23 Crossref
AbstractAbstract PDFPubReader   ePub   

Type 1 diabetes mellitus (T1DM) is a chronic autoimmune condition that requires life-long administration of insulin. Optimal management of T1DM entails a good knowledge and understanding of this condition both by the physician and the patient. Recent introduction of novel insulin preparations, technological advances in insulin delivery and glucose monitoring, such as continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring and improved understanding of the detrimental effects of hypoglycaemia and hyperglycaemia offer new opportunities and perspectives in T1DM management. Evidence from clinical trials suggests an important role of structured patient education. Our efforts should be aimed at improved metabolic control with concomitant reduction of hypoglycaemia. Despite recent advances, these goals are not easy to achieve and can put significant pressure on people with T1DM. The approach of physicians should therefore be maximally supportive. In this review, we provide an overview of the recent advances in T1DM management focusing on novel insulin preparations, ways of insulin administration and glucose monitoring and the role of metformin or sodium-glucose co-transporter 2 inhibitors in T1DM management. We then discuss our current understanding of the effects of hypoglycaemia on human body and strategies aimed at mitigating the risks associated with hypoglycaemia.

Citations

Citations to this article as recorded by  
  • A New Era in Islet Transplantation: Stem Cell-Derived and Gene-Edited Islet Therapies
    Joonyub Lee, Seung-Hwan Lee
    Diabetes & Metabolism Journal.2025; 49(6): 1201.     CrossRef
  • A cross-specialty expert opinion on the management of hair loss in gynaecological and endocrinological disorders in Indian patients
    K. Karthikeyan, N. Anand, Girish Parmar, Sandhya Jain
    International Journal of Research in Dermatology.2025; 12(1): 110.     CrossRef
  • Health-Related Quality of Life of Adolescents and Children With Type 1 Diabetes in the Jazan Region of Saudi Arabia
    Gassem A Gohal, Aqilah Majhali, Esaam Moafa, Sarah H Talebi, Bushra I Maashi, Amani Mutaen, Walaa J Alhamdan, Ibrahim M Dighriri
    Cureus.2024;[Epub]     CrossRef
  • An automatic deep reinforcement learning bolus calculator for automated insulin delivery systems
    Sayyar Ahmad, Aleix Beneyto, Taiyu Zhu, Ivan Contreras, Pantelis Georgiou, Josep Vehi
    Scientific Reports.2024;[Epub]     CrossRef
  • Nose-to-brain delivery of insulin nanoparticles for diabetes management: A review
    Manoj Kumbhare, Ajaykumar Surana, Pravin Morankar
    Baghdad Journal of Biochemistry and Applied Biological Sciences.2023; 4(02): 39.     CrossRef
  • Clinical Effects of a Home Care Pilot Program for Patients with Type 1 Diabetes Mellitus: A Retrospective Cohort Study
    Sejeong Lee, KyungYi Kim, Ji Eun Kim, Yura Hyun, Minyoung Lee, Myung-Il Hahm, Sang Gyu Lee, Eun Seok Kang
    Diabetes & Metabolism Journal.2023; 47(5): 693.     CrossRef
  • Impact of an Acceptance and Commitment Therapy programme on HbA1c, self-management and psychosocial factors in adults with type 1 diabetes and elevated HbA1c levels: a randomised controlled trial
    Ingrid Wijk, Susanne Amsberg, Unn-Britt Johansson, Fredrik Livheim, Eva Toft, Therese Anderbro
    BMJ Open.2023; 13(12): e072061.     CrossRef
  • Nose-to-brain delivery of insulin nanoparticles for diabetes management: A review
    Manoj Kumbhare, Ajaykumar Surana, Pravin Morankar
    Baghdad Journal of Biochemistry and Applied Biological Sciences.2023; 4(02): 39.     CrossRef
  • Role of sirtuin-1 (SIRT1) in hypoxic injury in pancreatic β-cells
    Ye-Jee Lee, Esder Lee, Young-Hye You, Yu-Bae Ahn, Ki-Ho Song, Ji-Won Kim, Seung-Hyun Ko
    Journal of Drug Targeting.2021; 29(1): 88.     CrossRef
  • Age at Diagnosis and the Risk of Diabetic Nephropathy in Young Patients with Type 1 Diabetes Mellitus
    Jong Ha Baek, Woo Je Lee, Byung-Wan Lee, Soo Kyoung Kim, Gyuri Kim, Sang-Man Jin, Jae Hyeon Kim
    Diabetes & Metabolism Journal.2021; 45(1): 46.     CrossRef
  • The impact of chemical engineering and technological advances on managing diabetes: present and future concepts
    Sabine Szunerits, Sorin Melinte, Alexandre Barras, Quentin Pagneux, Anna Voronova, Amar Abderrahmani, Rabah Boukherroub
    Chemical Society Reviews.2021; 50(3): 2102.     CrossRef
  • Surrogate markers and predictors of endogenous insulin secretion in children and adolescents with type 1 diabetes
    Jin-Na Yuan, Jian-Wei Zhang, Wayne S. Cutfield, Guan-Ping Dong, You-Jun Jiang, Wei Wu, Ke Huang, Xiao-Chun Chen, Yan Zheng, Bi-Hong Liu, José G. B. Derraik, Jun-Fen Fu
    World Journal of Pediatrics.2021; 17(1): 99.     CrossRef
  • Nano-based drug delivery systems used as vehicles to enhance polyphenols therapeutic effect for diabetes mellitus treatment
    Sónia Rocha, Mariana Lucas, Daniela Ribeiro, M. Luísa Corvo, Eduarda Fernandes, Marisa Freitas
    Pharmacological Research.2021; 169: 105604.     CrossRef
  • Dapagliflozin: an effective adjunctive treatment in type 1 diabetes
    Ghasem Yadegarfar, Mark Livingston, Gabriela Cortes, Ramadan Alshames, Kate Leivesley, Ann Metters, Linda Horne, Tom Steele, Adrian H. Heald
    Cardiovascular Endocrinology & Metabolism.2021; 10(2): 132.     CrossRef
  • Association between reduced serum levels of magnesium and the presence of poor glycemic control and complications in type 1 diabetes mellitus: A systematic review and meta-analysis
    Ana Kelen Rodrigues, Ana Elisa Melo, Caroline Pereira Domingueti
    Diabetes & Metabolic Syndrome: Clinical Research & Reviews.2020; 14(2): 127.     CrossRef
  • Insulin-Producing Cell Transplantation Platform for Veterinary Practice
    Suryo Kuncorojakti, Sayamon Srisuwatanasagul, Krishaporn Kradangnga, Chenphop Sawangmake
    Frontiers in Veterinary Science.2020;[Epub]     CrossRef
  • Type 1 Diabetes Home Care Project and Educational Consultation
    Eun Chong Shin
    The Journal of Korean Diabetes.2020; 21(2): 88.     CrossRef
  • Decision-Making in Artificial Intelligence: Is It Always Correct?
    Hun-Sung Kim
    Journal of Korean Medical Science.2020;[Epub]     CrossRef
  • The FreeStyle Libre flash glucose monitoring system: how it has improved glycaemic control for people with type 1 diabetes in Eastern Cheshire, UK
    Ghasem Yadegarfar, Simon G. Anderson, Zohaib Khawaja, Gabriela Cortes, Kathryn Leivesley, Ann Metters, Linda Horne, Tom Steele, Adrian H. Heald
    Cardiovascular Endocrinology & Metabolism.2020; 9(4): 171.     CrossRef
  • Dose-dependent effects of necrostatin-1 supplementation to tissue culture media of young porcine islets
    Hien Lau, Nicole Corrales, Samuel Rodriguez, Colleen Luong, Mohammadreza Mohammadi, Veria Khosrawipour, Shiri Li, Michael Alexander, Paul de Vos, Jonathan R. T. Lakey, Zoltán Rakonczay
    PLOS ONE.2020; 15(12): e0243506.     CrossRef
  • New Insulin Pumps and Open Source Artificial Pancreas System in Korea
    Jae Hyeon Kim
    The Journal of Korean Diabetes.2020; 21(4): 197.     CrossRef
  • Perspective and general approach of diabetes in palliative care
    Díaz Rodríguez Juan Javier
    Hospice and Palliative Medicine International Journal.2018;[Epub]     CrossRef
  • The effects of safranal, a constitute of saffron, and metformin on spatial learning and memory impairments in type-1 diabetic rats: behavioral and hippocampal histopathological and biochemical evaluations
    Fatemeh Delkhosh-Kasmaie, Amir Abbas Farshid, Esmaeal Tamaddonfard, Mehdi Imani
    Biomedicine & Pharmacotherapy.2018; 107: 203.     CrossRef
Original Articles
Clinical Care/Education
Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients
Mei Uemura, Yutaka Yano, Toshinari Suzuki, Taro Yasuma, Toshiyuki Sato, Aya Morimoto, Samiko Hosoya, Chihiro Suminaka, Hiromu Nakajima, Esteban C. Gabazza, Yoshiyuki Takei
Diabetes Metab J. 2017;41(4):265-274.   Published online July 31, 2017
DOI: https://doi.org/10.4093/dmj.2017.41.4.265
  • 12,104 View
  • 85 Download
  • 7 Web of Science
  • 4 Crossref
AbstractAbstract PDFPubReader   ePub   
Background

Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hyperglycemia using CGM data as a reference.

Methods

Thirty-eight inpatients with diabetes undergoing CGM were enrolled. MIET comprised a pretreatment step using a plastic microneedle array and glucose accumulation step with a hydrogel patch, which was placed on two sites from 9:00 AM to 5:00 PM or from 10:00 PM to 6:00 AM. IG AUC was calculated by accumulated glucose extracted by hydrogel patches using sodium ion as standard.

Results

A significant correlation was observed between the predicted AUC by MIET and CGM in daytime (r=0.76) and nighttime (r=0.82). The optimal cutoff for the IG AUC value of MIET to predict hyperglycemia over 200 mg/dL measured by CGM for 8 hours was 1,067.3 mg·hr/dL with 88.2% sensitivity and 81.5% specificity.

Conclusion

We showed that 8-hour IG AUC levels using MIET were valuable in estimating the blood glucose AUC without blood sampling. The results also supported the concept of using this technique for evaluating glucose excursion and for screening hyperglycemia during 8 hours in patients with diabetes at any time of day.

Citations

Citations to this article as recorded by  
  • LLM-Powered Prediction of Hyperglycemia and Discovery of Behavioral Treatment Pathways from Wearables and Diet
    Abdullah Mamun, Asiful Arefeen, Susan B. Racette, Dorothy D. Sears, Corrie M. Whisner, Matthew P. Buman, Hassan Ghasemzadeh
    Sensors.2025; 25(17): 5372.     CrossRef
  • Perioperative Glucose Pragmatic (PROGRAM) Trial: Standardized Insulin Management in Surgical Patients
    Matthew Zapf, C. Patrick Henson, Eunice Y. Huang, Jonathan P. Wanderer, Leslie C. Fowler, Karen Y. McCarthy, Robert E. Freundlich, Matthew S. Shotwell, Ronald Bell, Svetlana Eden, Miklos D. Kertai
    Anesthesiology.2025; 143(4): 883.     CrossRef
  • Efficacy of Postprandial Exercise in Mitigating Glycemic Responses in Overweight Individuals and Individuals with Obesity and Type 2 Diabetes—A Systematic Review and Meta-Analysis
    Jie Kang, Brian M. Fardman, Nicholas A. Ratamess, Avery D. Faigenbaum, Jill A. Bush
    Nutrients.2023; 15(20): 4489.     CrossRef
  • Multifunctional Wearable System that Integrates Sweat‐Based Sensing and Vital‐Sign Monitoring to Estimate Pre‐/Post‐Exercise Glucose Levels
    Yongseok Joseph Hong, Hyunjae Lee, Jaemin Kim, Minha Lee, Hyung Jin Choi, Taeghwan Hyeon, Dae‐Hyeong Kim
    Advanced Functional Materials.2018;[Epub]     CrossRef
Others
Satisfaction Survey on Information Technology-Based Glucose Monitoring System Targeting Diabetes Mellitus in Private Local Clinics in Korea
Hun-Sung Kim, So Jung Yang, Yoo Jin Jeong, Young-Eun Kim, Seok-Won Hong, Jae Hyoung Cho
Diabetes Metab J. 2017;41(3):213-222.   Published online June 21, 2017
DOI: https://doi.org/10.4093/dmj.2017.41.3.213
  • 10,583 View
  • 65 Download
  • 10 Web of Science
  • 10 Crossref
AbstractAbstract PDFPubReader   ePub   
Background

Private local clinics in Korea have little experience with information technology (IT)-based glucose monitoring (ITGM). Our aim is to examine user satisfaction and the possibility of using ITGM service practically.

Methods

Patients sent their blood glucose levels to physicians in local clinics. The physicians reviewed the blood glucose values online and provided personal consultations through text messaging or phone calls. Thereafter, a satisfaction survey on the ITGM service, the modified Morisky scale, and patient assessment of chronic illness care were administered.

Results

One hundred and seventy patients from seven private local clinics used the ITGM. Overall satisfaction, including that about the ITGM service, the device, and its usefulness, was rated higher than “mostly satisfied” (score 4.2±0.8 out of 5.0) and even higher among the elderly. Satisfaction was positively associated with age, especially in those older than 60 years. The main reason for intent for future use of the service was the time/place flexibility. Highly motivated patients tended to answer positively regarding information satisfaction (P=0.0377).

Conclusion

Our study is the first to investigate ITGM satisfaction in private local clinics. The feasibility of users utilizing ITGM should be clarified, and future clinical research on the service's clinical effects and cost-benefit analysis is needed.

Citations

Citations to this article as recorded by  
  • Evaluation of mobile health applications using the RE-AIM model: systematic review and meta-analysis
    Emanuele Louise Gomes de Magalhães Jorge, Emily de Souza Ferreira, Michele Duarte Pereira, Ana Luiza Paes Mingote, João Henrique Corrêa Silva, Tiago Ricardo Moreira, Rosângela Minardi Mitre Cotta
    Frontiers in Public Health.2025;[Epub]     CrossRef
  • Exploring Quantitative Methodologies for Assessing the Environmental, Social, and Economic Impacts of Telemedicine: A Literature Review
    Anna Savoldelli, Daniele Landi, Caterina Rizzi
    Sustainability.2024; 16(6): 2438.     CrossRef
  • Mobile solution and chronic diseases: development and implementation of a mobile application and digital platform for collecting, analyzing data, monitoring and managing health care
    Emily de Souza Ferreira, Ary Henrique Morais de Oliveira, Mateus Araújo Dias, Glauce Dias da Costa, José Pedro Toledo Januário, Glenda Michele Botelho, Rosângela Minardi Mitre Cotta
    BMC Health Services Research.2024;[Epub]     CrossRef
  • Telemedicine for Diabetes Mellitus Management in Older Adults: A Systematic Review
    Luca Schiliró Tristão, Guilherme Tavares, Francisco Tustumi, Wanderley Marques Bernardo, Márcio Luis Duarte, Maria Stella Peccin, Lucas Ribeiro dos Santos
    Current Diabetes Reviews.2023;[Epub]     CrossRef
  • The effectiveness of mobile application for monitoring diabetes mellitus and hypertension in the adult and elderly population: systematic review and meta-analysis
    Emily de Souza Ferreira, Fernanda de Aguiar Franco, Marina Marilac dos Santos Lara, André Amaral Levcovitz, Mateus Araújo Dias, Tiago Ricardo Moreira, Ary Henrique Morais de Oliveira, Rosângela Minardi Mitre Cotta
    BMC Health Services Research.2023;[Epub]     CrossRef
  • Effects of the Physician–Primary-Healthcare Nurse Telemedicine Model (P-NTM) on Medication Adherence and Health-Related Quality of Life (HRQoL) of Patients with Chronic Disease at Remote Rural Areas
    Mi Young Kwak, Eun Jeong Hwang, Tae Ho Lee
    International Journal of Environmental Research and Public Health.2021; 18(5): 2502.     CrossRef
  • Lessons from Use of Continuous Glucose Monitoring Systems in Digital Healthcare
    Hun-Sung Kim, Kun-Ho Yoon
    Endocrinology and Metabolism.2020; 35(3): 541.     CrossRef
  • Apprehensions about Excessive Belief in Digital Therapeutics: Points of Concern Excluding Merits
    Hun-Sung Kim
    Journal of Korean Medical Science.2020;[Epub]     CrossRef
  • Peripartum Management of Gestational Diabetes Using a Digital Health Care Service: A Pilot, Randomized Controlled Study
    Ji-Hee Sung, Da Young Lee, Kyoung Pil Min, Cheol-Young Park
    Clinical Therapeutics.2019; 41(11): 2426.     CrossRef
  • Mobile Phone–Based Telemedicine Practice in Older Chinese Patients with Type 2 Diabetes Mellitus: Randomized Controlled Trial
    Chenglin Sun, Lin Sun, Shugang Xi, Hong Zhang, Huan Wang, Yakun Feng, Yufeng Deng, Haimin Wang, Xianchao Xiao, Gang Wang, Yuan Gao, Guixia Wang
    JMIR mHealth and uHealth.2019; 7(1): e10664.     CrossRef
Others
Evaluation of a Novel Glucose Area Under the Curve (AUC) Monitoring System: Comparison with the AUC by Continuous Glucose Monitoring
Satoshi Ugi, Hiroshi Maegawa, Katsutaro Morino, Yoshihiko Nishio, Toshiyuki Sato, Seiki Okada, Yasuo Kikkawa, Toshihiro Watanabe, Hiromu Nakajima, Atsunori Kashiwagi
Diabetes Metab J. 2016;40(4):326-333.   Published online July 26, 2016
DOI: https://doi.org/10.4093/dmj.2016.40.4.326
  • 14,784 View
  • 131 Download
  • 6 Web of Science
  • 8 Crossref
AbstractAbstract PDFPubReader   ePub   
Background

Management of postprandial hyperglycemia is a key aspect in diabetes treatment. We developed a novel system to measure glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET) for simple monitoring of postprandial glucose excursions. In this study, we evaluated the relationship between our system and continuous glucose monitoring (CGM) by comparing glucose AUC obtained using MIET with that obtained using CGM for a long duration.

Methods

Twenty diabetic inpatients wearing a CGM system were enrolled. For MIET measurement, a plastic microneedle array was applied to the skin as pretreatment, and hydrogels were placed on the pretreated area to collect interstitial fluid. Hydrogels were replaced every 2 or 4 hours and AUC was predicted on the basis of glucose and sodium ion levels.

Results

AUC predicted by MIET correlated well with that measured by CGM (r=0.93). Good performances of both consecutive 2- and 4-hour measurements were observed (measurement error: 11.7%±10.2% for 2 hours and 11.1%±7.9% for 4 hours), indicating the possibility of repetitive measurements up to 8 hours. The influence of neither glucose fluctuation nor average glucose level over the measurement accuracy was observed through 8 hours.

Conclusion

Our system showed good relationship with AUC values from CGM up to 8 hours, indicating that single pretreatment can cover a large portion of glucose excursion in a day. These results indicated possibility of our system to contribute to convenient monitoring of glucose excursions for a long duration.

Citations

Citations to this article as recorded by  
  • Phytochemical screening of ethanolic extract of Kopasanda (Chromolaena odorata (L) RM King and H Rob) leaves and its anti-hyperglycaemic activity in the mouse model of hyperglycaemia
    Sofia Vivi, Ruzana Atiya, Fujiko Muflihah
    Scripta Medica.2026; 57(1): 15.     CrossRef
  • A review on exploring the emerging role of novel transdermal gel drug delivery systems for skin diseases
    Prince Nikhil Rathore, Anirban Pal, Sakshi Pandey, Sayani Maji, Alpana Ram
    Next Research.2025; 2(3): 100373.     CrossRef
  • LLM-Powered Prediction of Hyperglycemia and Discovery of Behavioral Treatment Pathways from Wearables and Diet
    Abdullah Mamun, Asiful Arefeen, Susan B. Racette, Dorothy D. Sears, Corrie M. Whisner, Matthew P. Buman, Hassan Ghasemzadeh
    Sensors.2025; 25(17): 5372.     CrossRef
  • Effects of insulin glargine U300 versus insulin degludec U100 on glycemic variability, hypoglycemia, and diet evaluated by continuous glucose monitoring in type 1 diabetes: a retrospective cross‐sectional study
    Pin‐Lun Tsai, Chia‐Hung Lin, Yu‐Yao Huang, Hsin‐Yun Chen, Yi‐Hsuan Lin
    The Kaohsiung Journal of Medical Sciences.2024; 40(12): 1086.     CrossRef
  • Continuous glucose monitoring metrics and pregnancy outcomes in insulin‐treated diabetes: A post‐hoc analysis of the GlucoMOMS trial
    Doortje Rademaker, Anne W. T. van der Wel, Rik van Eekelen, Daphne N. Voormolen, Harold W. de Valk, Inge M. Evers, Ben Willem Mol, Arie Franx, Sarah E. Siegelaar, Bas B. van Rijn, J. Hans DeVries, Rebecca C. Painter
    Diabetes, Obesity and Metabolism.2023; 25(12): 3798.     CrossRef
  • Regimen comprising GLP-1 receptor agonist and basal insulin can decrease the effect of food on glycemic variability compared to a pre-mixed insulin regimen
    Yi-Hsuan Lin, Chia-Hung Lin, Yu-Yao Huang, Hsin-Yun Chen, An-Shun Tai, Shih-Chen Fu, Sheng-Hwu Hsieh, Jui-Hung Sun, Szu-Tah Chen, Sheng-Hsuan Lin
    European Journal of Medical Research.2022;[Epub]     CrossRef
  • Advantages of Applying Artificial Intelligent System to Medical Neurology (Preprint)
    Zhenqiang Fu, Jingtao Wang, Jingtao Wang
    JMIR Medical Informatics.2020;[Epub]     CrossRef
  • Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients
    Mei Uemura, Yutaka Yano, Toshinari Suzuki, Taro Yasuma, Toshiyuki Sato, Aya Morimoto, Samiko Hosoya, Chihiro Suminaka, Hiromu Nakajima, Esteban C. Gabazza, Yoshiyuki Takei
    Diabetes & Metabolism Journal.2017; 41(4): 265.     CrossRef
1,5-Anhydroglucitol as a Useful Marker for Assessing Short-Term Glycemic Excursions in Type 1 Diabetes
Hannah Seok, Ji Hye Huh, Hyun Min Kim, Byung-Wan Lee, Eun Seok Kang, Hyun Chul Lee, Bong Soo Cha
Diabetes Metab J. 2015;39(2):164-170.   Published online March 9, 2015
DOI: https://doi.org/10.4093/dmj.2015.39.2.164
  • 10,946 View
  • 73 Download
  • 33 Web of Science
  • 32 Crossref
AbstractAbstract PDFPubReader   ePub   
Background

Type 1 diabetes is associated with more severe glycemic variability and more frequent hypoglycemia than type 2 diabetes. Glycemic variability is associated with poor glycemic control and diabetic complications. In this study, we demonstrate the clinical usefulness of serum 1,5-anhydroglucitol (1,5-AG) for assessing changes in glycemic excursion in type 1 diabetes.

Methods

Seventeen patients with type 1 diabetes were enrolled in this study. A continuous glucose monitoring system (CGMS) was applied twice at a 2-week interval to evaluate changes in glycemic variability. The changes in serum glycemic assays, including 1,5-AG, glycated albumin and hemoglobin A1c (HbA1c), were also evaluated.

Results

Most subjects showed severe glycemic excursions, including hypoglycemia and hyperglycemia. The change in 1,5-AG level was significantly correlated with changes in the glycemic excursion indices of the standard deviation (SD), mean amplitude of glucose excursion (MAGE), lability index, mean postmeal maximum glucose, and area under the curve for glucose above 180 mg/dL (r=-0.576, -0.613, -0.600, -0.630, and -0.500, respectively; all P<0.05). Changes in glycated albumin were correlated with changes in SD and MAGE (r=0.495 and 0.517, respectively; all P<0.05). However, changes in HbA1c were not correlated with any changes in the CGMS variables.

Conclusion

1,5-AG may be a useful marker for the assessment of short-term changes in glycemic variability. Furthermore, 1,5-AG may have clinical implications for the evaluation and treatment of glycemic excursions in type 1 diabetes.

Citations

Citations to this article as recorded by  
  • Efficacy and safety of needle-free injection in patients with type 2 diabetes mellitus undergoing intensive insulin therapy: a randomized controlled trial based on the flash glucose monitoring system
    Jing Wang, Zibo Liu, Lijing Jiao, Jing Zhou, Ting Wang, Caige Li, Qian Wang, Lingling Yuan, Fang Zhang, Guizhi Li, Qiuxiao Zhu, Siyao Jin, Lihui Zhang
    Frontiers in Endocrinology.2026;[Epub]     CrossRef
  • Untargeted Metabolomics Identifies N‐Lactoyl‐Amino Acids as Dose‐Responsive Plasma Biomarkers of Metformin Adherence in Type 2 Diabetes
    Tomas Cajka, Jiri Hricko, Lucie Rudl Kulhava, Michaela Paucova, Michaela Novakova, Veronika Hola, Stanislava Rakusanova, Oliver Fiehn, Vojtech Skop, Ivana Lankova, Iva Miskova, Terezie Pelikanova, Martin Haluzik
    Clinical Pharmacology & Therapeutics.2026; 119(4): 1057.     CrossRef
  • Biochemical characterization of 1,5-anhydro-D-glucitol kinase from Clostridium symbiosum ATCC 14940
    Dan Guo, Bangyu Li, Hua Huang, Xinshuai Zhang
    Biochemical and Biophysical Research Communications.2026; 825: 153949.     CrossRef
  • Precision nutrition in Asian populations: a Multi-omics review of mechanisms, biomarkers, and implementation pathways
    Minjoo Kim
    Journal of Nutritional Science.2026;[Epub]     CrossRef
  • Limitations of glycated hemoglobin and emerging biomarkers for diabetes care after bariatric surgery
    Uchenna Esther Okpete, Haewon Byeon
    World Journal of Diabetes.2025;[Epub]     CrossRef
  • Detecting Hyperglycemia Using Biomarkers Versus Continuous Glucose Monitoring
    Natalie Rula Daya, Michael Fang, Jung-Im Shin, James S. Pankow, Pamela L. Lutsey, Arielle Valint, Justin B. Echouffo-Tcheugui, Scott Zeger, Elizabeth Selvin
    Diabetes Care.2025; 48(8): 1446.     CrossRef
  • Mobile health intervention to reduce HbA1c in type 2 diabetes: a quasi-experimental study in Indonesian primary care
    Asti Rindarwati, Lia Amalia, Hikmat Permana
    Pharmacia.2025; 72: 1.     CrossRef
  • Metabolomics Signatures of Atherosclerosis in Cardiovascular Disease: A Narrative Systematic Review
    Monica Pibiri, Antonio Noto, Antonio Dalu, Sandro Muntoni, Karolina Krystyna Kopeć, Martina Spada, Luigi Atzori, Cristina Piras
    Journal of Clinical Medicine.2025; 14(22): 8028.     CrossRef
  • Association of hemoglobin glycation index with all-cause mortality in critically ill patients with atrial fibrillation: a retrospective analysis from MIMIC-IV
    Chao Wu, Xuejun Hu, Long Tang, Zufei Wu, Zheng Huang, Cunming Fang
    BMC Cardiovascular Disorders.2025;[Epub]     CrossRef
  • Digital Behavior Change Interventions to Reduce Sedentary Behavior and Promote Physical Activity in Adults with Diabetes: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Xiaoyan Zhang, Xue Qiao, Ke Peng, Shan Gao, Yufang Hao
    International Journal of Behavioral Medicine.2024; 31(6): 959.     CrossRef
  • The correlation between serum 1, 5-anhydroglucitol and β-cell function in Chinese adults with different glucose metabolism statuses
    Yuexing Yuan, Yuanyuan Tan, Yao Wang, Shanhu Qiu, Jiao Yang, Cheng Chen
    International Journal of Diabetes in Developing Countries.2024; 44(4): 799.     CrossRef
  • The progress of clinical research on the detection of 1,5-anhydroglucitol in diabetes and its complications
    Huijuan Xu, Junhua Pan, Qiu Chen
    Frontiers in Endocrinology.2024;[Epub]     CrossRef
  • Glycation and Glucose Variability in Subjects with Type 1 Diabetes
    V. V. Klimontov, D. M. Bulumbaeva, J. F. Semenova
    Biochemistry (Moscow), Supplement Series B: Biomedical Chemistry.2024; 18(1): 59.     CrossRef
  • The clinical potential of 1,5-anhydroglucitol as biomarker in diabetes mellitus
    Haiying Xu, Renyin Chen, Xiaoli Hou, Na Li, Yanwei Han, Shaoping Ji
    Frontiers in Endocrinology.2024;[Epub]     CrossRef
  • Glycemic dispersion: a new index for screening high glycemic variability
    Rui Shi, Lei Feng, Yan-Mei Liu, Wen-Bo Xu, Bei-Bei Luo, Ling-Tong Tang, Qian-Ye Bi, Hui-Ying Cao
    Diabetology & Metabolic Syndrome.2023;[Epub]     CrossRef
  • DBS are suitable for 1,5-anhydroglucitol monitoring in GSD1b and G6PC3-deficient patients taking SGLT2 inhibitors to treat neutropenia
    Joseph P. Dewulf, Nathalie Chevalier, Sandrine Marie, Maria Veiga-da-Cunha
    Molecular Genetics and Metabolism.2023; 140(3): 107712.     CrossRef
  • HbA1c combined with glycated albumin or 1,5‐anhydroglucitol improves the efficiency of diabetes screening in a Chinese population
    Junyi Qian, Cheng Chen, Xiaohang Wang, Yuanyuan Tan, Jiao Yang, Yuexing Yuan, Juan Chen, Haijian Guo, Bei Wang, Zilin Sun, Yao Wang
    Diabetic Medicine.2022;[Epub]     CrossRef
  • Assessment of glycemia in chronic kidney disease
    Mohamed Hassanein, Tariq Shafi
    BMC Medicine.2022;[Epub]     CrossRef
  • Continuous subcutaneous insulin infusion alters microRNA expression and glycaemic variability in children with type 1 diabetes
    Emma S. Scott, Andrzej S. Januszewski, Luke M. Carroll, Gregory R. Fulcher, Mugdha V. Joglekar, Anandwardhan A. Hardikar, Timothy W. Jones, Elizabeth A. Davis, Alicia J. Jenkins
    Scientific Reports.2021;[Epub]     CrossRef
  • Red rice koji extract alleviates hyperglycemia by increasing glucose uptake and glucose transporter type 4 levels in skeletal muscle in two diabetic mouse models
    Takakazu Yagi, Koji Ataka, Kai-Chun Cheng, Hajime Suzuki, Keizaburo Ogata, Yumiko Yoshizaki, Kazunori Takamine, Ikuo Kato, Shouichi Miyawaki, Akio Inui, Akihiro Asakawa
    Food & Nutrition Research.2020;[Epub]     CrossRef
  • How tightly controlled do fluctuations in blood glucose levels need to be to reduce the risk of developing complications in people with Type 1 diabetes?
    R. Livingstone, J. G. Boyle, J. R. Petrie
    Diabetic Medicine.2020; 37(4): 513.     CrossRef
  • Resolution on the results of the first working meeting of the scientific advisory board «Actual problems of glycemic variability as a new criterion of glycemic control and safety of diabetes therapy»
    Mikhail B. Antsiferov, Gagik R. Galstyan, Alexey V. Zilov, Alexander Y. Mayorov, Tatyana N. Markova, Nikolay A. Demidov, Olga M. Koteshkova, Dmitry N. Laptev, Alisa V. Vitebskaya
    Diabetes mellitus.2019; 22(3): 281.     CrossRef
  • Hyperglycemia and Carotenoid Intake Are Associated with Serum Carotenoids in Youth with Type 1 Diabetes
    Namrata Sanjeevi, Leah M. Lipsky, Tonja R. Nansel
    Journal of the Academy of Nutrition and Dietetics.2019; 119(8): 1340.     CrossRef
  • Correlation of Serum 1,5-AG with Uric Acid in Type 2 Diabetes Mellitus with Different Renal Functions
    Kai Zhang, Bizhen Xue, Yuexing Yuan, Yao Wang
    International Journal of Endocrinology.2019; 2019: 1.     CrossRef
  • Glycaemic control and glycaemic variability in older people with diabetes
    Hermes J Florez
    The Lancet Diabetes & Endocrinology.2018; 6(6): 433.     CrossRef
  • Alternate glycemic markers reflect glycemic variability in continuous glucose monitoring in youth with prediabetes and type 2 diabetes
    Christine L. Chan, Laura Pyle, Megan M. Kelsey, Lindsey Newnes, Amy Baumgartner, Philip S. Zeitler, Kristen J. Nadeau
    Pediatric Diabetes.2017; 18(7): 629.     CrossRef
  • 1,5-anidroglucitolo: un marcatore non tradizionale di iperglicemia
    Gabriella Lavalle, Roberto Testa, Maria Elisabetta Onori, Raffaella Vero, Anna Vero
    La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine.2017; 13(3-4): 139.     CrossRef
  • Glycemic control and variability in association with body mass index and body composition over 18months in youth with type 1 diabetes
    Leah M. Lipsky, Benjamin Gee, Aiyi Liu, Tonja R. Nansel
    Diabetes Research and Clinical Practice.2016; 120: 97.     CrossRef
  • Postprandial dysmetabolism: Too early or too late?
    Christos Pappas, Eleni A. Kandaraki, Sofia Tsirona, Dimitrios Kountouras, Georgia Kassi, Evanthia Diamanti-Kandarakis
    Hormones.2016; 15(3): 321.     CrossRef
  • How Can We Easily Measure Glycemic Variability in Diabetes Mellitus?
    Suk Chon
    Diabetes & Metabolism Journal.2015; 39(2): 114.     CrossRef
  • Alternative biomarkers for assessing glycemic control in diabetes: fructosamine, glycated albumin, and 1,5-anhydroglucitol
    Ji-Eun Lee
    Annals of Pediatric Endocrinology & Metabolism.2015; 20(2): 74.     CrossRef
  • Glycemic Variability: How Do We Measure It and Why Is It Important?
    Sunghwan Suh, Jae Hyeon Kim
    Diabetes & Metabolism Journal.2015; 39(4): 273.     CrossRef
Effectiveness of 3-Day Continuous Glucose Monitoring for Improving Glucose Control in Type 2 Diabetic Patients in Clinical Practice
Soo Kyoung Kim, Hye Jeong Kim, Taehun Kim, Kyu Yeon Hur, Sun Wook Kim, Moon-Kyu Lee, Yong-Ki Min, Kwang-Won Kim, Jae Hoon Chung, Jae Hyeon Kim
Diabetes Metab J. 2014;38(6):449-455.   Published online December 15, 2014
DOI: https://doi.org/10.4093/dmj.2014.38.6.449
  • 10,848 View
  • 50 Download
  • 21 Web of Science
  • 20 Crossref
AbstractAbstract PDFPubReader   ePub   
Background

The aim of this study was to investigate whether adjusting diabetic treatment regimens according to the information obtained from a continuous glucose monitoring system (CGMS) might lead to improved glycemic control in patients with type 2 diabetes.

Methods

We reviewed the medical charts of 172 patients who used the CGMS for 1 year starting in December 2008 and the records of 1,500 patients who visited their regular outpatient clinics during December 2008. Of these patients, a total of 65 CGMS patients and 301 regular outpatients (control group) were enrolled in the study after propensity score matching. There were no differences in baseline glycated hemoglobin (HbA1c), age, and duration of diabetes between the CGMS and the control groups after propensity score matching. The changes in the HbA1c levels from baseline to 6 months were calculated.

Results

The CGMS group showed a significant improvement in the HbA1c level compared to the control group at 3 months (7.9%±1.6% vs. 7.4%±1.2%, P=0.001) and at 6 months (7.4%±1.2% vs. 7.9%±1.6%, P=0.010). There were significant differences in the treatment modality changes between the CGMS group and the control group.

Conclusion

Using a 3-day CGMS was advantageous for improving glucose control in patients with type 2 diabetes and may help these patients to optimize glycemic control in clinical practice.

Citations

Citations to this article as recorded by  
  • Clinical Impact of Continuous Glucose Monitoring in Noninsulin Treated Type 2 Diabetes: A Review
    Grazia Aleppo, Anders L. Carlson, Janet B. McGill, Hamza Alshannaq, Rodolfo Galindo, Davida Kruger, Carol J. Levy, Jessica Y. Matuoka, Sabrina Ilham, Guillermo Umpierrez, Gregory J. Norman
    Diabetes Technology & Therapeutics.2026; 28(7): 639.     CrossRef
  • Advanced Hybrid Closed‐Loop Insulin Delivery Is Associated With Improved Glycemic Indicators and Normalization of Small Nerve Fibre Structure in Adults With Type 1 Diabetes
    Hoda Gad, Einas Elgassim, Kawsar Mohamed Ayon Mohamud, Najlaa Sultan Al‐Naimi, Hamad Ali Al‐Sharshani, Ibrahim Mohammed, Mariam A. Al‐Malaheem, Dorothy J. Quadros, Alhanoof AlJalahma, Neila Lamine, Ahmad Yaser Alhaddad, Hussein Ahmed Hussein Zaky Aly, Joh
    Journal of the Peripheral Nervous System.2025;[Epub]     CrossRef
  • Continuous glucose monitoring in noninsulin‐treated type 2 diabetes: A critical review of reported trials with an updated systematic review and meta‐analysis of randomised controlled trials
    Ronnie Aronson, Alexander Abitbol, Harpreet S. Bajaj, Alice Y. Y. Cheng, Stavroula Christopoulos, Stewart B. Harris, Akshay B. Jain, Ronald M. Goldenberg
    Diabetes, Obesity and Metabolism.2025; 27(11): 6220.     CrossRef
  • Effectiveness of continuous glucose monitoring in patient management of Type 2 Diabetes Mellitus: an umbrella review of systematic reviews from 2011 to 2024
    Yong Yi Tan, Enhui Suan, Gerald Choon Huat Koh, Suhana Binte Suhairi, Shilpa Tyagi
    Archives of Public Health.2024;[Epub]     CrossRef
  • Biological and Clinical Impacts of Glucose Metabolism in Pancreatic Ductal Adenocarcinoma
    Zhao Liu, Hiromitsu Hayashi, Kazuki Matsumura, Norio Uemura, Yuta Shiraishi, Hiroki Sato, Hideo Baba
    Cancers.2023; 15(2): 498.     CrossRef
  • Professional continuous glucose monitoring in patients with diabetes mellitus: A systematic review and meta‐analysis
    Sergio Di Molfetta, Irene Caruso, Angelo Cignarelli, Annalisa Natalicchio, Sebastio Perrini, Luigi Laviola, Francesco Giorgino
    Diabetes, Obesity and Metabolism.2023; 25(5): 1301.     CrossRef
  • American Association of Clinical Endocrinology Clinical Practice Guideline: The Use of Advanced Technology in the Management of Persons With Diabetes Mellitus
    George Grunberger, Jennifer Sherr, Myriam Allende, Thomas Blevins, Bruce Bode, Yehuda Handelsman, Richard Hellman, Rosemarie Lajara, Victor Lawrence Roberts, David Rodbard, Carla Stec, Jeff Unger
    Endocrine Practice.2021; 27(6): 505.     CrossRef
  • Lack of Acceptance of Digital Healthcare in the Medical Market: Addressing Old Problems Raised by Various Clinical Professionals and Developing Possible Solutions
    Jong Il Park, Hwa Young Lee, Hyunah Kim, Jisan Lee, Jiwon Shinn, Hun-Sung Kim
    Journal of Korean Medical Science.2021;[Epub]     CrossRef
  • A head‐to‐head comparison of personal and professional continuous glucose monitoring systems in people with type 1 diabetes: Hypoglycaemia remains the weak spot
    Othmar Moser, Marlene Pandis, Felix Aberer, Harald Kojzar, Daniel Hochfellner, Hesham Elsayed, Melanie Motschnig, Thomas Augustin, Philipp Kreuzer, Thomas R. Pieber, Harald Sourij, Julia K. Mader
    Diabetes, Obesity and Metabolism.2019; 21(4): 1043.     CrossRef
  • Glucose monitoring in diabetes: from clinical studies to real‐world practice
    Rebecca C Sagar, Afroze Abbas, Ramzi Ajjan
    Practical Diabetes.2019; 36(2): 57.     CrossRef
  • The Effectiveness of Continuous Glucose Monitoring in Patients with Type 2 Diabetes: A Systematic Review of Literature and Meta-analysis
    Cindy Park, Quang A. Le
    Diabetes Technology & Therapeutics.2018; 20(9): 613.     CrossRef
  • Effects of Dapagliflozin on 24-Hour Glycemic Control in Patients with Type 2 Diabetes: A Randomized Controlled Trial
    Robert R. Henry, Poul Strange, Rong Zhou, Jeremy Pettus, Leon Shi, Sergey B. Zhuplatov, Traci Mansfield, David Klein, Arie Katz
    Diabetes Technology & Therapeutics.2018; 20(11): 715.     CrossRef
  • Clinical and economic benefits of professional CGM among people with type 2 diabetes in the United States: analysis of claims and lab data
    Joseph A. Sierra, Mona Shah, Max S. Gill, Zachery Flores, Hiten Chawla, Francine R. Kaufman, Robert Vigersky
    Journal of Medical Economics.2018; 21(3): 225.     CrossRef
  • Role of continuous glucose monitoring for type 2 in diabetes management and research
    Robert Vigersky, Maneesh Shrivastav
    Journal of Diabetes and its Complications.2017; 31(1): 280.     CrossRef
  • Assessing the Therapeutic Utility of Professional Continuous Glucose Monitoring in Type 2 Diabetes Across Various Therapies: A Retrospective Evaluation
    Jothydev Kesavadev, Robert Vigersky, John Shin, Pradeep Babu Sadasivan Pillai, Arun Shankar, Geethu Sanal, Gopika Krishnan, Sunitha Jothydev
    Advances in Therapy.2017; 34(8): 1918.     CrossRef
  • Use of Continuous Glucose Monitoring in Youth-Onset Type 2 Diabetes
    Christine L. Chan
    Current Diabetes Reports.2017;[Epub]     CrossRef
  • The efficacy and safety of adding either vildagliptin or glimepiride to ongoing metformin therapy in patients with type 2 diabetes mellitus
    Gyuri Kim, Sewon Oh, Sang-Man Jin, Kyu Yeon Hur, Jae Hyeon Kim, Moon-Kyu Lee
    Expert Opinion on Pharmacotherapy.2017; 18(12): 1179.     CrossRef
  • Morning Spot Urine Glucose-to-Creatinine Ratios Predict Overnight Urinary Glucose Excretion in Patients With Type 2 Diabetes
    So Ra Kim, Yong-ho Lee, Sang-Guk Lee, Sun Hee Lee, Eun Seok Kang, Bong-Soo Cha, Hyun Chul Lee, Jeong-Ho Kim, Byung-Wan Lee
    Annals of Laboratory Medicine.2017; 37(1): 9.     CrossRef
  • The Contemporary Role of Masked Continuous Glucose Monitoring in a Real-Time World
    Ian Blumer
    Journal of Diabetes Science and Technology.2016; 10(3): 790.     CrossRef
  • Glycemic Variability: How Do We Measure It and Why Is It Important?
    Sunghwan Suh, Jae Hyeon Kim
    Diabetes & Metabolism Journal.2015; 39(4): 273.     CrossRef
The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System
Young Ha Baek, Heung Yong Jin, Kyung Ae Lee, Seon Mee Kang, Woong Ji Kim, Min Gul Kim, Ji Hyun Park, Soo Wan Chae, Hong Sun Baek, Tae Sun Park
Korean Diabetes J. 2010;34(6):350-358.   Published online December 31, 2010
DOI: https://doi.org/10.4093/kdj.2010.34.6.350
  • 15,381 View
  • 103 Download
  • 15 Crossref
AbstractAbstract PDFPubReader   ePub   
Background

Clinical experience with the continuous glucose monitoring systems (CGMS) is limited in Korea. The objective of this study is to evaluate the accuracy of the CGMS and the correlation between interstitial fluid and venous plasma glucose level in Korean healthy male subjects.

Methods

Thirty-two subjects were served with glucose solution contained same amount of test food's carbohydrate and test foods after separate overnight fasts. CGMS was performed over 3 days during hopitalization for each subjects. Venous plasma glucose measurements were carried out during 4 hours (0, 0.25, 0.5, 0.75, 1, 2, 4 hours) just before and after glucose solution and test food load. The performance of the CGMS was evaluated by comparing its readings to those obtained at the same time by the hexokinase method using the auto biochemistry machine (Hitachi 7600-110). Also, correlations between glucose recorded with CGMS and venous plasma glucose value were examined.

Results

CGMS slightly underestimated the glucose value as compared with the venous plasma glucose level (16.3 ± 22.2 mg/dL). Correlation between CGMS and venous plasma glucose values throughout sensor lifetime is 0.73 (regression analysis: slope = 1.08, intercept = 8.38 mg/dL). Sensor sensitivity can deteriorate over time, with correlations between venous blood glucose and CGMS values dropping from 0.77 during 1st day to 0.65 during 2nd and 3rd day.

Conclusion

The accuracy of data provided by CGMS may be less than expected. CGMS sensor sensitivity is decreased with the passage of time. But, from this study, CGMS can be used for glucose variability tendency monitoring conveniently to the Korean.

Citations

Citations to this article as recorded by  
  • Glucose monitoring intelligent tracking system for remote glycemic assessment in diabetic dogs: a novel approach
    Jiri Xi, Heer Yang, Qiang Zhang, Sicheng Yang, Fan Ping, Xiucai Fang
    BMC Veterinary Research.2025;[Epub]     CrossRef
  • Evaluation of the performance and usability of a novel continuous glucose monitoring system
    Li Yan, Qiang Li, Qingbo Guan, Mingsong Han, Yu Zhao, Junfei Fang, Jiajun Zhao
    International Journal of Diabetes in Developing Countries.2023; 43(4): 551.     CrossRef
  • Correlation between short- and mid-term hemoglobin A1c and glycemic control determined by continuous glucose monitoring
    Jen-Hung Huang, Yung-Kuo Lin, Ting-Wei Lee, Han-Wen Liu, Yu-Mei Chien, Yu-Chun Hsueh, Ting-I Lee, Yi-Jen Chen
    Diabetology & Metabolic Syndrome.2021;[Epub]     CrossRef
  • Accuracy of Flash Glucose Monitoring During Postprandial Rest and Different Walking Conditions in Overweight or Obese Young Adults
    Xiaoyuan Zhang, Fenghua Sun, Waris Wongpipit, Wendy Y. J. Huang, Stephen H. S. Wong
    Frontiers in Physiology.2021;[Epub]     CrossRef
  • The MEDGICarb-Study: Design of a multi-center randomized controlled trial to determine the differential health-promoting effects of low- and high-glycemic index Mediterranean-style eating patterns
    Robert E. Bergia, Izabela Biskup, Rosalba Giacco, Giuseppina Costabile, Savanna Gray, Amy Wright, Marilena Vitale, Wayne W. Campbell, Rikard Landberg, Gabriele Riccardi
    Contemporary Clinical Trials Communications.2020; 19: 100640.     CrossRef
  • A genetic programming-based regression for extrapolating a blood glucose-dynamics model from interstitial glucose measurements and their first derivatives
    I. De Falco, A. Della Cioppa, A. Giugliano, A. Marcelli, T. Koutny, M. Krcma, U. Scafuri, E. Tarantino
    Applied Soft Computing.2019; 77: 316.     CrossRef
  • Genetic Programming-based induction of a glucose-dynamics model for telemedicine
    Ivanoe De Falco, Antonio Della Cioppa, Tomas Koutny, Michal Krcma, Umberto Scafuri, Ernesto Tarantino
    Journal of Network and Computer Applications.2018; 119: 1.     CrossRef
  • A high-accuracy measurement method of glucose concentration in interstitial fluid based on microdialysis
    Dachao Li, Qingmei Xu, Yu Liu, Ridong Wang, Kexin Xu, Haixia Yu
    Measurement Science and Technology.2017; 28(11): 115701.     CrossRef
  • Effects of Higher Dietary Protein and Fiber Intakes at Breakfast on Postprandial Glucose, Insulin, and 24-h Interstitial Glucose in Overweight Adults
    Akua Amankwaah, R. Sayer, Amy Wright, Ningning Chen, Megan McCrory, Wayne Campbell
    Nutrients.2017; 9(4): 352.     CrossRef
  • High Surface Area Electrodes Generated via Electrochemical Roughening Improve the Signaling of Electrochemical Aptamer-Based Biosensors
    Netzahualcóyotl Arroyo-Currás, Karen Scida, Kyle L. Ploense, Tod E. Kippin, Kevin W. Plaxco
    Analytical Chemistry.2017; 89(22): 12185.     CrossRef
  • Hyperglycemia-Induced Changes in Hyaluronan Contribute to Impaired Skin Wound Healing in Diabetes: Review and Perspective
    Sajina Shakya, Yan Wang, Judith A. Mack, Edward V. Maytin
    International Journal of Cell Biology.2015; 2015: 1.     CrossRef
  • Hypoglycemia in everyday life after gastric bypass and duodenal switch
    Niclas Abrahamsson, Britt Edén Engström, Magnus Sundbom, F Anders Karlsson
    European Journal of Endocrinology.2015; 173(1): 91.     CrossRef
  • The use of reinforcement learning algorithms to meet the challenges of an artificial pancreas
    Melanie K Bothe, Luke Dickens, Katrin Reichel, Arn Tellmann, Björn Ellger, Martin Westphal, Ahmed A Faisal
    Expert Review of Medical Devices.2013; 10(5): 661.     CrossRef
  • Continuous glucose monitoring: current clinical use
    Hun‐Sung Kim, Jeong‐Ah Shin, Jin‐Sun Chang, Jae‐Hyoung Cho, Ho‐Young Son, Kun‐Ho Yoon
    Diabetes/Metabolism Research and Reviews.2012; 28(s2): 73.     CrossRef
  • Correlations of Glucose Levels in Interstitial Fluid Estimated by Continuous Glucose Monitoring Systems and Venous Plasma
    Byung-Joon Kim
    Korean Diabetes Journal.2010; 34(6): 338.     CrossRef
Randomized Controlled Trial
Establishment of Blood Glucose Monitoring System using Internet.
Hee Soo Kim, Jae Hyoung Cho, Hyuk Sang Kwon, Jin Hee Lee, Bok Re Song, Jung A Oh, Kun Ho Yoon, Ho Young Son
Korean Diabetes J. 2003;27(3):280-287.   Published online June 1, 2003
  • 2,222 View
  • 25 Download
AbstractAbstract PDF
BACKGROUND
The internet has been used world wide as a communication tool. To improve the quality of glucose control, the effectiveness of an Internet-based Blood Glucose Monitoring System (IBGMS), on changes in HbA1c levels, was investigated. RESEARCH DESIGN AND METHODS: A randomized clinical trial, involving 110 patients who had visited outpatient's clinic at the Kangnam St. Mary's Hospital diabetes center for 3 months, was conducted. The study subjects were treated with IBGMS for 12 weeks, with a control group receiving the usual outpatient management for the same period. HbA1C and other laboratory tests were performed at the baseline and at the end of the study. RESULTS: There were no significant differences found between the two groups at the baseline measurements, with respect to age, sex, diabetes duration, body mass index, blood pressure, HbA1C and other laboratory data. In the follow up tests, the study group showed a significant reduction in the HbA1C level, by 7.1% (0.54% absolute, p=0.001), while the control group showed an increased HbA1C level (p=0.054). Moreover, there was an 11.1% reduction (0.92% absolute, p<0.001) in the HbA1C level in the patients with HbA1C levels > or =7.0% at baseline in the study group, but those with HbA1C levels <7.0% maintained good HbA1c levels, 6.32%, by the end of the study. CONCLUSIONS: This new IBGMS resulted in a significant reduction in the HbA1C levels during the study period. We propose this IBGMS as a new method for glycemic control.
Original Article
Effect of Self-monitoring of Blood Glucose on Pregnancy Outcome in Women with Mild Gestational Diabetes.
Hak Chul Jang, Jeong Eun Park, Chang Hoon Yim, Ho Yeun Chung, Ki Ok Han, Hyun Koo Yoon, In Kwon Han, Moon Young Kim, Jae Hyug Yang, Mi Jung Kim, Sun Young Ko, Yeon Kyung Lee
Korean Diabetes J. 2001;25(1):93-102.   Published online February 1, 2001
  • 3,025 View
  • 47 Download
AbstractAbstract PDF
BACKGROUND
Self-monitoring of blood glucose (SMBG) and intensive therapy with insulin demonstrated to have a positive effects in the reduction of the neonatal complications in women with gestational diabetes (GDM). However the utility of SMBG in the mild GDM who does not requiring insulin has not been formally reported. Therefore, to evaluate the effectiveness of SMBG in the management of mild GDM, we compared the pregnancy outcome and the postpartum glucose tolerance of women who monitored their glycemic control by SMBG to those of women who monitored by laboratory glucose test at each office visit during pregnancy. METHODS: We studied 185 women diagnosed as a GDM by NDDG criteria and their fasting glucose concentration < 5.8 mM. All subjects had singleton pregnancy,and no medical diseases that may affect fetal growth, and were certain of gestational age by early ultrasonography. They were treated with an identical GDM management protocol except glucose monitoring. One hundred five women were monitored by laboratory glucose test at each office visit (office group) and 80 women were monitored by SMBG (SMBG group). Pregnancy outcome including rates of cesarian section, obstetric complication, LGA infant and glucose tolerance status at postpartum were compared between two groups. RESULTS: The age, height, prepregnancy weight, weight at delivery and parity were not significantly different between the two groups. Fasting, 1-h, 2-h glucose concentration during the diagnostic test of GDM in SMBG group were similar to those of office group. However, 3-h glucose concentration of office group was 0.3 mM higher than that of SMBG group. The rate of primary cesarian section, preterm labor and pregnancy-induced hypertension of SMBG group were similar to those of office group. The mean postprandial 2-h glucose concentration of office group measured at each office was 0.5 mM higher than that of SMBG group. Although 5% of office group were treated with insulin, 24% of SMBG group were requiring insulin therapy. The birth weight and LGA infant rate of office group were 3403 432 g and 28%, those were heavier and higher than those of SMBG group (3169 447 g, 13.8%). The 90% of office group and 84% of SMBG group were performed 75 g oral glucose tolerance test at postpartum 6-8 weeks. There was no significant difference in rates of diabetes and IGT between office and SMBG group (9.5%, 11.6%; 7.5%, 9.0% respectively). CONCLUSIONS: This study demonstrated that SMBG is very seful in early detection of maternal hyperglycemia and lowing the postprandial glucose, as well as reducing the rate of LGA infants in women with mild GDM.

Diabetes Metab J : Diabetes & Metabolism Journal
Close layer
TOP